All Products
-
Petroleum Testing Instruments
-
Lubricating Oil And Grease Antifreeze Testing Instruments
-
Diesel Fuel Testing Equipment
-
Transformer Oil Testing Equipment
-
Feed Testing Instrument
-
Pharmaceutical Testing Instruments
-
Edible Oil Testing Equipment
-
Chemical Analysis Instruments
-
Lube Oil Testing Equipment
-
Flour Test Instrument
-
Food Testing Instruments
-
Crude Oil Testing Equipment
-
Hydraulic Oil Testing Equipment
-
Flash Point Tester
-
Kinematic Viscosity Tester
-
Freezing Point Tester
-
Cone Penetration Apparatus
Phone Number :
+8615665870097
WhatsApp :
+8613805402265
ISO—2719Low temperature closed flash point instrument, compressor refrigeration, electronic ignition
MODEL: | SH105C |
---|---|
Power Supply: | AC(220±10%)V, 50Hz |
Flash Point Measuring Range: | (0 ~ +350)℃ |
SH102D Fully automatic constant temperature petroleum density meter with a precision of 0.5% and 1/1000
MODEL: | SH102D1 |
---|---|
Measurement Range Of Density: | 0.0001~1.999g/cm3 |
Density Measurement Accuracy: | ± 0.0005g/cm3 |
Principle of Titration Neutralization Method SH108A Fully Automatic Oil Acid Number Meter Essential for Refineries
MODEL: | SH108A |
---|---|
Range: | 0.001~3.000mgKOH/g |
Power Rate: | 300 W |
ASTM D974 Gasoline and kerosene acidity detection SH108B reflux automatic acidity tester Automatic titration
MODEL: | SH108B |
---|---|
Power Supply: | AC220V± 20% 50Hz± 10% |
Measuring Range: | 0.001-2.0mgKOH/g |
Heavy oil and crude oil motion viscometer ASTM D445 manual lofting and automatic judgment 4 holes
MODEL: | SH112 |
---|---|
Power Supply: | AC 220V ± 10%, 50HZ ± 5% |
Heating Power: | 1800W |
Fully automatic petroleum product pour point tester Single hole SH113E glass test tube automatic tilting method
MODEL: | SH113E |
---|---|
Compliance With Standard: | GB/T510 |
Temperature Range: | +30 ℃~-70 ℃ |
Principle of Titration Neutralization Method SH108 Oil Acid Number Tester Essential for oil refineries
MODEL: | SH108 |
---|---|
Power Supply: | 220V±10%,50Hz±1% |
Ambient Temperature: | 10 ℃ ~ +30℃ |
Essence and fragrances Determination of flash point SH105E automatic Binsky Martin closed flash point tester
MODEL: | SH105E |
---|---|
Working Power Supply: | AC220V ± 10%, 50Hz |
Method Of Use: | Binsky Martin Closed Cup Method |
SH105D balance method low-temperature closed flash point tester for closed flash point detection of paints and paints
MODEL: | SH105D |
---|---|
Power Supply: | AC 220V±10%, 50 Hz |
Flash Point Measurement Range: | -30~100°C |
Automatic calculation results of SH101C automatic mechanical impurity content analyzer (with balance)
MODEL: | SH101C |
---|---|
Temperature: | 4-way PID Temperature Control |
Temperature Control Range: | Room Temperature~100 ℃ |