All Products
-
Petroleum Testing Instruments
-
Lubricating Oil And Grease Antifreeze Testing Instruments
-
Diesel Fuel Testing Equipment
-
Transformer Oil Testing Equipment
-
Feed Testing Instrument
-
Pharmaceutical Testing Instruments
-
Edible Oil Testing Equipment
-
Chemical Analysis Instruments
-
Lube Oil Testing Equipment
-
Flour Test Instrument
-
Food Testing Instruments
-
Crude Oil Testing Equipment
-
Hydraulic Oil Testing Equipment
-
Flash Point Tester
-
Kinematic Viscosity Tester
-
Freezing Point Tester
-
Cone Penetration Apparatus
Phone Number :
+8615665870097
WhatsApp :
+8613805402265
Hair Friction Tensile Tester Single Experiment Resolution 0.01 360mm Itinerary ST-16A
| Force Sensing Element (Loadcell): | 0.5, 1, 2, 5, 10, 20, 30, 50Kg (choose One) |
|---|---|
| Force Resolution: | 0.01N |
| Deformation Resolution: | 0.01mm |
Texture Hardness Tester Singlechip 1-500mm/min Travel distance 360mm ST-16A
| Force Sensing Element: | 2. 5, 10, 20, 30, 50, 100kg |
|---|---|
| Force Resolution: | 0.01kg |
| Deformation Resolution: | 0.01mm |
Meat Tenderness Tester 0 ~ 250N Speed 1-1000mm/min Displacement 1-300mm NY/T 1180
| Measurement Range: | 0 ~ 250N |
|---|---|
| Resolution: | 0.01N |
| Accuracy Of Indication: | <±1% |
Touch Screen Texture Instrument Resolution 0.01 speed 1-500mm/min PQT ST-16A
| Force Sensing Element: | 0.5, 1, 2, 5, 10, 20, 30, 50, 100kg |
|---|---|
| Force Resolution: | 0.01kg |
| Deformation Resolution: | 0.01mm |
Potential Drop Point Meter Edible Oleic Acid Value Range ≥ 0.001mgkoh/G Gb5009.227
| Measurement Range: | ≥ 0.001 MgKOH/g |
|---|---|
| Potential Measurement Range: | -2000.0 ~ +2000.0 MV |
| Basic Error Of Electronic Unit: | 0.1% F·S ± 0.1 MV |
Level 0.5 Semi-Automatic Potential Dropper 0-100℃ 2000 Sets Storage Error 0.2% ST-13
| Instrument Level: | Level 0.5 |
|---|---|
| Temp Measurement: | 0-100℃ |
| Repetitive Error In Capacity Analysis: | 0.2% |
Automatic Constant Temp Polarimeter -45°~+45° -120°Z~+120°Z 30kg GB/T35887
| Measurement Range: | -45°~+45°, -120°Z~+120°Z |
|---|---|
| Minimum Reading Value: | 0.001°, 0.01° Z |
| Accuracy: | ± (0.01 °+measured Value × 0.05%), ± (0.03 °+measured Value × 0.05%) Z |
Automatic Touch Screen Sugar Detector 15 - 35℃ Wavelength 589.3nm GB/T35887
| Measurement Range: | Optical Rotation ± 89.99° Sugar ± 259°Z |
|---|---|
| Measurement Accuracy: | ± 0.01° (-45°≤ Optical Rotation ≤+45°) ± 0.02°(when Optical Rotation <- 45° Or Optical Rotation >+45°) |
| Temp Control Range: | 15℃ -35℃ (Peltier) |
Automatic Sugar Detector Dark Colored Sample 0.001° 0.01°Z Optical Rotation GB/T35887
| Measurement Range: | -45° ~ +45°; -120°Z~+120°Z |
|---|---|
| Minimum Reading Value: | 0.001°; 0.01°Z |
| Accuracy: | ± (0.01°+measured Value * 0.05%); ± (0.03°+measured Value * 0.05%) Z |
Semi-Automatic Kjeldahl Nitrogen Analyzer 8 Holes Range 0.1-200mg Nitrogen GB/T6432
| Measurement Range: | Nitrogen Content 0.05-90% (0.1-200mg Nitrogen) |
|---|---|
| Accuracy: | Relative Difference Of 1% |
| Number Of Holes: | 8 Holes |