All Products
-
Petroleum Testing Instruments
-
Lubricating Oil And Grease Antifreeze Testing Instruments
-
Diesel Fuel Testing Equipment
-
Transformer Oil Testing Equipment
-
Feed Testing Instrument
-
Pharmaceutical Testing Instruments
-
Edible Oil Testing Equipment
-
Chemical Analysis Instruments
-
Lube Oil Testing Equipment
-
Flour Test Instrument
-
Food Testing Instruments
-
Crude Oil Testing Equipment
-
Hydraulic Oil Testing Equipment
-
Flash Point Tester
-
Kinematic Viscosity Tester
-
Freezing Point Tester
-
Cone Penetration Apparatus
Phone Number :
+8613220512573
WhatsAPP :
+8613220512573
2 Work Units Toluene Method Herbal Preparation Moisture Meter Heating Power 1000W USP<921>
| Round-bottom Flask: | 500ml Short-neck |
|---|---|
| Work Unit: | 2 Units |
| Straight Condenser Tube Length: | 40cm |
Auto Karl Fischer Titration Moisture Analyzer Test 0.001% ~ 100% Voltage 0 ~ 2499mv ASTM E203
| Method Principle: | Karl Fischer Volumetric Titration |
|---|---|
| Polarization Voltage: | 0 ~ 2499 Mv |
| Moisture Content Measurement Range: | 0.001% ~ 100% |
Auto Volumetric Karl Fischer Moisture Analyzer Test 30ppm ~ 100% Sensitivity 10 ~ 6A ChP 2025
| Measurement Range: | 30ppm ~ 100% (H2O Mass Fraction) |
|---|---|
| Resolution: | 0.01ml |
| Repeatability Of Moisture Titratio: | ≤0.01 |
Glucose Atropine Sulfate Optical Rotation Analyzer Measure -45° ~ +45° Temp 10 ~ 40℃ EP 2.2.7
| Measurement Range: | -45° ~ +45° |
|---|---|
| Minimum Reading Value: | 0.001° |
| Constant Temp Water Bath: | 10℃ ~ 40℃ |
250L Medication Stability Test Chamber Timing 1 ~ 9999h Temp Control 0 ~ 65℃ ChP
| Internal Volume: | 250L (Custom Sizes Available) |
|---|---|
| Temp Control Range: | 0 ~ 65℃ |
| Temp Control Fluctuation: | ±0.5℃ |
Medical Digital Auto Tablet Hardness Tester With Printer Measure 10N ~ 400N Diameter 2 ~ 20mm ChP
| Measurement Pressure: | 10N ~ 400N (1kg ~ 40kg) |
|---|---|
| Measurement Diameter: | 2 ~ 20mm |
| Measurement Accuracy: | ± 0.1% |
Touch Screen Auto Medication Relative Density Meter 0.001 ~ 1.999g/Cm³ Temp Control 20℃ EP 2.2.5
| Temp Control Method: | Peltier Temp Control |
|---|---|
| Temp Control Range: | 20℃ |
| Density Resolution: | 0.001g/cm³ |
Digital Vibration Density Meter 500g Sample Amplitude Max 15mm Torsion 0.86N.M ASTM B527
| Weight Of The Tested Sample: | ≤ 500.00g |
|---|---|
| Volume Of Compacted Sample: | ≤ 250ml |
| Counting Method: | Photoelectric Induction |
Automatic Medication Relative Density Meter Measure 0.001 ~ 1.999g/Cm³ Data Storage 80 Sets USP<699>
| Measurement Range Of Density: | 0.001 ~ 1.999g/cm³ |
|---|---|
| Density Measurement Accuracy: | ±0.001g/cm³ |
| Density Resolution: | ± 0.001g/cm³ |
Automatic Compaction Density Analyzer Sample ≤500.00g Touchscreen Display ISO 3953
| Display Method: | Touchscreen Display |
|---|---|
| Weight Of The Test Sample: | ≤500.00g |
| Compacted Specimen Volume: | ≤250.00ml |

