All Products
-
Petroleum Testing Instruments
-
Lubricating Oil And Grease Antifreeze Testing Instruments
-
Diesel Fuel Testing Equipment
-
Transformer Oil Testing Equipment
-
Feed Testing Instrument
-
Pharmaceutical Testing Instruments
-
Edible Oil Testing Equipment
-
Chemical Analysis Instruments
-
Lube Oil Testing Equipment
-
Flour Test Instrument
-
Food Testing Instruments
-
Crude Oil Testing Equipment
-
Hydraulic Oil Testing Equipment
-
Flash Point Tester
-
Kinematic Viscosity Tester
-
Freezing Point Tester
-
Cone Penetration Apparatus
Phone Number :
+8615665870097
WhatsApp :
+8613805402265
Fully Automatic Tablet Hardness Tester with Microprinter and 220V Power Supply
Measurement Pressure: | 10N-400N (1kg-40kg) |
---|---|
Measuring Diameter: | 2-20mm |
Measurement Accuracy: | ± 0.1% |
Automatic Drug Relative Density Meter with 7-inch TFT Display and 0.001g/cm3 Resolution
Density Resolution: | 0.001g/cm3 |
---|---|
Repeatability: | ± 0.001g/cm3 |
Accuracy: | ± 0.001g/cm3 |
Fully Automatic Cone Penetrometer 10-50℃ with 0.01mm Accuracy Compliant with Chinese Pharmacopoeia 0983
Measurement Range: | 1-700 Cone Penetration |
---|---|
Constant Temperature Method: | Built-in Refrigeration |
Cone Penetration Accuracy: | ± 1 Cone Penetration Degree |
Automatic Drug Relative Density Meter with U-Shaped Oscillating Tube Method for ChP 0601 Compliance
Measurement Range Of Density: | 0.001~1.999g/cm3 |
---|---|
Density Measurement Accuracy: | ± 0.001g/cm3 |
Sampling Volume: | 2ml/time |
Automatic Compaction Density Tester for Ceramic Powder with Max 400rpm and Sample 500g ISO 3953
Display Mode: | Touch Screen Display |
---|---|
Weight Of The Tested Sample: | ≤ 500.00 Grams |
Volume Of Compacted Sample: | ≤ 250.00 Milliliters |
Digital Powder Compaction Density Meter with 250ml Sample Volume 0.86 N.m Torque and AC 220V Power Supply
Weight Of The Tested Sample: | ≤ 500.00g |
---|---|
Volume Of Compacted Sample: | ≤ 250ml |
Single Vibration Frequency: | ≤ 0~99999 Times (when Set To 0 Times, The Output Is "loose Packing Density") |
Fully Automatic Protein Analyzer Kjeldahl Nitrogen Determinator 0.1-240 mg N RSD ≤ 0.5% ChP 0731
Analysis Range: | 0.1-240 Mg N |
---|---|
Precision (RSD): | ≤ 0.5% |
Recovery: | 99-101% (± 1%) |
ST212B Fully Automatic Vaseline Drop Point Tester with 0.1℃ Resolution and GB1790 Compliance
Temp Measurement Range: | RT ~ 400 ℃ |
---|---|
Test Route: | 2 Routes |
Resolution: | 0.1 ℃ |
Manual Vaseline Drip Point Instrument with 110mm Glass Test Tube 250rpm Mixing Motor and 400W Heater
Bathtub: | Insulated Double-layer Bathtub |
---|---|
Test Tube: | Glass Test Tube: Total Length 110mm, Inner Diameter 25mm |
Heater: | Tubular, Power 400W |
ST204A Fully Automatic Ubbelohde Kinematic Viscometer USP 911 Compliant Chinese Pharmacopoeia 2025 5-100 ℃
Temp Measurement Range: | 5-100 ℃ (with Refrigeration) |
---|---|
Temp Control Accuracy: | 0.1 ℃ (customizable To 0.01 ℃) |
Measurement Range: | 0.6-1000mm2/s |