All Products
-
Petroleum Testing Instruments
-
Lubricating Oil And Grease Antifreeze Testing Instruments
-
Diesel Fuel Testing Equipment
-
Transformer Oil Testing Equipment
-
Feed Testing Instrument
-
Pharmaceutical Testing Instruments
-
Edible Oil Testing Equipment
-
Chemical Analysis Instruments
-
Lube Oil Testing Equipment
-
Flour Test Instrument
-
Food Testing Instruments
-
Crude Oil Testing Equipment
-
Hydraulic Oil Testing Equipment
-
Flash Point Tester
-
Kinematic Viscosity Tester
-
Freezing Point Tester
-
Cone Penetration Apparatus
Phone Number :
+8615665870097
WhatsApp :
+8613805402265
ISO 3679 Low Temperature Closed Flash Point Tester Balancing Method 2ml Sample
Flash Point Detection Range: | (-30 ~ +100) ℃ |
---|---|
Sample Size: | 2ml |
Data Storage: | 200 Sets |
2ml Sample Full Automatic Essence Closed Flash Point Meter ISO 3679 -30 ~ +100℃
Flash Point Detection Range: | (-30 ~ +100) ℃ |
---|---|
Sample Size: | 2ml |
Temperature Control Accuracy: | ± 0.1 ℃ |
Fully Automatic Apparent Viscosity Tester ASTM D5293 Engine Oil Data Store 1000 Sets
Temperature Range: | Normal Temperature ~ -70 ℃ |
---|---|
Data Storage: | 1000 Sets |
Viscosity Measurement Range: | 1200-20000 MPa. S |
Potentiometric Titration Automatic PH Meter ASTMD664 10ml Burette Min Titration 0.001mL
Measurement Range: | ≥ 0.001 MgKOH/g |
---|---|
Potential Measurement Range: | -2000.0 ~ +2000.0 MV |
Minimum Titration Volume: | 0.001mL |
Fully Automatic Oleic Acid Value Tester ASTM D974 1-6 Oil Samples Accuracy ± 0.005mgKOH/G
Range: | 0.001 ~ 3.000mgKOH/g |
---|---|
Accuracy: | ± 0.005mgKOH/g |
Resolution: | 0.001mgKOH/g |
Transformer Oil Fully Automatic Acidity Analyzer ASTM D974 Range 0.001~2.0 MgKOH/G
Method Used: | Reflux Method (fully Comply With National Standards) |
---|---|
Display: | 7-inch LCD Touch Screen |
Measurement Range: | 0.001~2.0 MgKOH/g |
3 Oil Samples Transformer Oleic Acid Value Tester ASTM D974 Measure 7min Power 300W
Measurement Method: | Titration Neutralization Method |
---|---|
Measurement Time: | 7 Minutes |
Samples: | 1-3 Oil Samples |
Automatic Residual Carbon Analyzer Astm D4530 Micro Method 0.10%M/M-30.0%M/M
Measurement Range: | 0.10% (m/m) -30.0% (m/m) |
---|---|
Temp Range: | Room Temp -500 ℃ |
Set Time Error: | <0.1s |
Fully Automatic Open Flash Point And Ignition Point Tester ASTMD92 Accuracy 0.5%
Temp Measurement Range: | Room Temp ~ 400 ℃ |
---|---|
Repeatability: | Flash Point ≤ 150 ℃, Error ± 2 ℃; Flash Point ≥ 150 ℃, Error ± 3 ℃ |
Resolution: | 0.1 ℃ |
Fully Automatic Cleveland Open Flash Point Tester ASTMD92 Lubricating Oil Rt ~ 400 ℃
Repeatability: | Flash Point ≤ 150 ℃, Error ± 2 ℃ Flash Point ≥ 150 ℃, Error ± 3 ℃ |
---|---|
Resolution: | 0.1 ℃ |
Heating Rate: | Compliant With GB/T3536 Standard |