All Products
-
Petroleum Testing Instruments
-
Lubricating Oil And Grease Antifreeze Testing Instruments
-
Diesel Fuel Testing Equipment
-
Transformer Oil Testing Equipment
-
Feed Testing Instrument
-
Pharmaceutical Testing Instruments
-
Edible Oil Testing Equipment
-
Chemical Analysis Instruments
-
Lube Oil Testing Equipment
-
Flour Test Instrument
-
Food Testing Instruments
-
Crude Oil Testing Equipment
-
Hydraulic Oil Testing Equipment
-
Flash Point Tester
-
Kinematic Viscosity Tester
-
Freezing Point Tester
-
Cone Penetration Apparatus
Phone Number :
+8613220512573
WhatsAPP :
+8613220512573
Keywords [ sulfur content tester ] match 33 Products.
UV Fluorescence Sulfur Meter RT ~ 1200 ℃ Measure 0.1 ~ 10000mg/L Ppm ASTM D5435
| Measurement Range: | 0.1 ~ 10000mg/L(ppm) |
|---|---|
| Detection Limit: | 0.1mg/L (ppm) (sulfur Element) |
| Temp Control Range: | RT ~ 1200 ℃ |
ASTM D5453 Ultraviolet Fluorescence Sulfur Meter Computer Control Operations
| MODEL: | SH0689 |
|---|---|
| Working Power Supply: | AC220V±10% 50HZ |
| Required Environmental: | Environmental Temperature Is 15-40 ℃; Humidity ≤ 85% |
ASTM D3227 Automatic Mercaptan Sulfur Tester Potentiometric Titration Method
| MODEL: | SH709 |
|---|---|
| Measurement Range: | 0.0003% ~ 0.01%(3PPM-100PPM) |
| Potential Measurement Range: | 0 ~ ±1999.5 MV |
ASTM D5453 Diesel Fuel Testing Equipment Ultraviolet Fluorescence UV Sulfur Analyzer
| Size: | 550 ×560× 400 (mm) |
|---|---|
| Measurement Range: | 0.1mg/L~10000mg/L ~% |
| Configuration: | Host (data Acquisition, Control System), Cracking Furnace, Autosampler And Computer (operating Software Included). |
SH708 Chemiluminescence Method Trace Nitrogen Content Analyzer as Per ASTM D4629 and ASTM D5762
| MODEL: | SH708 |
|---|---|
| Temperature Control Range: | Room Temperature ~ 1050℃ |
| Temperature Control Accuracy: | ±3℃ |
SH201 Gasification Injector Flash Evaporator For Liquid Hydrocarbons Trace Sulfur Arsenic
| MODEL: | SH201 |
|---|---|
| Power Supply: | 220V ± 10%, 50Hz ± 1Hz. |
| Operating Environment: | Temperature 5 ℃ - 35 ℃; The Humidity Is Lower Than 75%. |
Automatic mercaptan and sulfur measuring instrument using potential titration method SH709
| MODEL: | SH709 |
|---|---|
| Measurement Range: | 0.0003% ~ 0.01%(3PPM-100PPM) |
| Precision: | R =0.00007+0.027X1 |
SH709 automatic mercaptan and sulfur measuring instrument using potential titration method measurement principle.
| MODEL: | SH709 |
|---|---|
| Measurement Range: | 0.0003% ~ 0.01%(3PPM-100PPM) |
| Potential Measurement Range: | 0 ~ ±1999.5 MV |
Determination Of Trace Nitrogen In Liquid Petroleum Testing Instruments Chemiluminescence Method
| MODEL: | SH708 |
|---|---|
| Power Supply: | AC220V±22V,50Hz±0.5Hz,1500 W |
| Temperature Range: | Room Temperature~1050℃ |
Pre treatment gasification sampler for liquid hydrocarbon analysis SH201
| MODEL: | SH201 |
|---|---|
| Power Supply: | 220V ± 10%, 50Hz ± 1Hz. |
| Operating Environment: | Temperature 5 ℃ - 35 ℃ |

