UV Fluorescence Sulfur Meter RT ~ 1200 ℃ Measure 0.1 ~ 10000mg/L Ppm ASTM D5435
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
x| Measurement Range | 0.1 ~ 10000mg/L(ppm) | Detection Limit | 0.1mg/L (ppm) (sulfur Element) |
|---|---|---|---|
| Temp Control Range | RT ~ 1200 ℃ | Temp Control Accuracy | ±1℃ |
| Working Power Supply | AC220V±10% 50HZ | Ambient Temp | 15 ~ 40℃ |
| Highlight | UV fluorescence sulfur meter ASTM D5435,lube oil sulfur tester 0.1-10000mg/L,high-temperature sulfur meter RT-1200℃ |
||
SH0689 UV fluorescence sulfur meter
The UV fluorescence sulfur analyzer adopts the principle of UV fluorescence measurement and is suitable for measuring the total sulfur content in crude oil, distillate oil, liquefied petroleum gas, plastics, petrochemical products, food, etc.
After being introduced into the high-temperature cracking furnace, the sample undergoes a cracking oxidation reaction. At a high temperature of around 1000 ℃, the sample is completely gasified and undergoes oxidative cracking, with sulfides quantitatively converted into sulfur dioxide. The reaction gas is carried by the carrier gas, and the water is removed by the membrane dryer before entering the reaction chamber. Sulfur dioxide is exposed to specific wavelengths of ultraviolet radiation, absorbing this radiation and causing some electrons to turn towards high-energy orbitals. Once electrons return to their original orbitals, excess energy is released in the form of light and detected by photomultiplier tubes at specific wavelengths. The emitted fluorescence is completely specific to sulfur and proportional to the sulfur content in the original sample. After amplification by a microcurrent amplifier and computer data processing, it can be converted into an electrical signal directly proportional to the light intensity. By measuring its size, the sulfur content of the corresponding sample can be calculated.
The SH0689 UV fluorescence sulfur analyzer complies with ASTM D5453, SH/T 0689-2000 and other standards
| Product model | SH0689 |
| Product Name | UV fluorescence sulfur analyzer |
| Manufacturer | Shandong Shengtai Instrument Co., Ltd |
| Testing items | Applicable to the determination of total sulfur content in crude oil, distillate oil, liquefied petroleum gas, plastics, Petrochemical, food, etc |
| Standards | ASTM D5453,SH/T 0689-2000 |
| Simple technical features or parameters | Computer controlled operation, enabling human-machine dialogue |
Main features
● Computer controlled operation can achieve human-machine dialogue, and data and peak shapes can be automatically stored and printed.
● The operating software can be connected to the LIMIS system to achieve automatic data transmission.
● The instrument adopts a new type of quartz cracking tube, which can increase the injection volume and reduce measurement errors.
● The Computer fan is automatically turned on and off, which saves time and labor by eliminating the trouble of waiting for the sample to be turned off.
● The darkroom system adopts new foreign technology, and key components use imported detection components to improve the detection accuracy of the instrument.
● The instrument adopts imported membrane dryer to absorb water, which saves the trouble of replacing Magnesium perchlorate frequently and reduces the problem of air leakage.
● The use of computer control for temperature has improved the temperature control accuracy of the instrument and is not prone to overheating.
● Replacing water cooling with air cooling saves water resources.
● You can retrieve existing calibration curves and calibrate them with standard samples for sample analysis.
Technical Parameters
| Measurement range | 0.1 ~ 10000mg/L(ppm) |
| Detection limit | 0.1mg/L (ppm) (sulfur element) |
| Repetitive error |
1.0mg/L<X≤10mg/L Cv≤±10% 10mg/L<X Cv≤±5% |
| Gas source requirements |
high-purity oxygen: above 99.98%; High purity argon gas: above 99.98% (self provided) |
| Temp control range | RT ~ 1200 ℃ |
| Temp control accuracy | ±1℃ |
| Working power supply | AC220V±10% 50HZ |
| Ambient temp | 15 ~ 40℃ |
| Relative humidity | ≤85% |
| Instrument size | 550×560×400mm |
| Instrument weight | 10kg |
Note: The appearance pictures, dimensions, volume and weight of the instrument are for reference only. If there are any updates to the instrument, they may be slight changes without prior notice.
Packing list
| Number | Name | Quantity | Unit | Note |
| 1 | Host | 1 | Set | |
| 2 | Sampler | 1 | Set | |
| 3 | Computer | 1 | Set | With 232 serial port |
| 4 | Quartz tube | 1 | Piece | Provided by the installer |
| 5 | Elbow | 1 | Piece | |
| 6 | Pipe joint clamp | 1 | Piece | |
| 7 | Quartz tube fixing clip | 2 | Piece | Ceramic ring |
| 8 | Polytetrafluoroethylene pipe | 10 | M | |
| 9 | Silicone rubber tube | 0.2 | M | inner diameter Ф5 |
| 10 | Silicone rubber tube | 0.2 | M | inner diameter Ф3 |
| 11 | Membrane dryer | 1 | Piece | Imported from Japan |
| 12 | Power cord | 2 | Piece | |
| 13 | Power line of cracking furnace | 1 | Piece | |
| 14 | Communication cable | 1 | Piece | |
| 15 | Air line pressing cap | 2 | Piece | |
| 16 | Silicone rubber pad | 20 | Piece | |
| 17 | Sampling probe | Each 2 | Piece | 10ul,25ul |
| 18 | Standard sample | 4 | Box | Installed with |
| 19 | Fuse tube 20A | 4 | Piece | |
| 20 | Fuse tube 2A | 4 | Piece | |
| 21 | Warranty card certificate | 1 | Copy | |
| 22 | Instruction manual | 1 | Copy |
![]()
Shandong Shengtai Instrument Co., Ltd. provides the following quality assurance for the instruments sold to you:
----The provided instrument materials are brand new, meet national quality standards, and have a manufacturer's certificate of conformity;
----The materials and main components provided meet the technical requirements specified in the technical documentation;
----The overall quality assurance period of the equipment is one year (excluding normal wear and tear of vulnerable parts).
----We are responsible for free maintenance of any instrument quality issues that occur during the warranty period. Due to equipment malfunction caused by the user's responsibility, we are responsible for repairing and charging reasonable fees.
----Lifetime discounted supply of parts for equipment, and lifetime maintenance and repair of the entire machine.
----After the expiration of the warranty period, if the user needs maintenance and technical services, we will only charge a cost fee.