Fully Automatic Closed Flash Point Tester ASTM D93 Transformer Room Temp ~ 370 ℃
| Temp Measurement: | Room Temp ~ 370 ℃ |
|---|---|
| ≥ 104 ℃ Accuracy: | ± 2 ℃ |
| ≤104℃ Accuracy: | ±1℃ |
70ml Sample Manual Closed Flash Point Tester ASTM D93 Heating Rate 1-12 ℃/Min
| Instrument Weight: | 6 Kg |
|---|---|
| Instrument Size: | 310 * 300 * 290 Mm |
| Depth Of Oil Testing Capacity Marking Line: | 33.9-34.3 Mm |
ASTM D93 ABC Step Conversion Of National Standard Fully Automatic Closed Flash Point Tester SH105BS
| MODEL: | SH105BS |
|---|---|
| Working Power Supply: | AC220V±10%, 50Hz |
| Step A: | Heating Rate: 5 ~ 6℃/min |
500W DIesel Fuel Testing Equipment Automatic Closed Flash Point Tester Electronic Ignition
| Standard: | ASTM D93 |
|---|---|
| Size: | 450 ×380× 350 (mm) |
| Relative Humidity: | ≤65% |
Automatic Closed Flash Point Tester RT - 370℃ Electronic Ignition 0.5% Precision ASTM D93
| Temp Control Range: | RT ~ 370℃ |
|---|---|
| Temp Accuracy: | ≥104℃, ±2℃; ≤104℃, ±1℃ |
| Ignition Method: | Electronic Ignition |
SH705 Intelligent Closed Flash Point Tester ASTM D93 Electric Ignition
| Temp Range: | Room Temp+5 ℃ ~ 300 ℃ |
|---|---|
| Temp Measurement: | PT100 Platinum Resistance (Class A) |
| Accuracy: | ± 2 ℃ |
Fully Automatic Closed Flash Point Tester RT ~ 300℃ Mixing 90r-120r/min ASTM D93
| Measurement Range: | Room Temperature ~ 300 ℃ |
|---|---|
| Display: | Large Screen LCD Module Display |
| Mode A Heating Rate: | 5 ℃ - 6 ℃/min |
Low Temperature Closed Flash Point Tester ASTM D 93 Compressor Refrigeration
| Flash Point Detection Range: | (0 ~ +350) ℃8 |
|---|---|
| Temp Control Accuracy: | ± 0.1 ℃ |
| Experimental Volume: | 75 ~ 80ml |
Electric Diesel Manual Closed Flash Point Tester
| Working Power Supply: | AC220V±10%, 50Hz |
|---|---|
| Heating Device: | Heating Power From 0 ~ 600W Continuously Adjustable |
| The Sample Heating Rate: | 1 ~ 12℃/ Min |
Manual ASTM D93 Flash Point Tester Binsky Martin Closed Mouth Cup Method
| STandard: | ASTM D93 |
|---|---|
| Key Words: | Binsky-Martin Closed Cup Method Flash Point Tester |
| Test Range: | Room Temperature To 300℃ |