All Products
-
Petroleum Testing Instruments
-
Lubricating Oil And Grease Antifreeze Testing Instruments
-
Diesel Fuel Testing Equipment
-
Transformer Oil Testing Equipment
-
Feed Testing Instrument
-
Pharmaceutical Testing Instruments
-
Edible Oil Testing Equipment
-
Chemical Analysis Instruments
-
Lube Oil Testing Equipment
-
Flour Test Instrument
-
Food Testing Instruments
-
Crude Oil Testing Equipment
-
Hydraulic Oil Testing Equipment
-
Flash Point Tester
-
Kinematic Viscosity Tester
-
Freezing Point Tester
-
Cone Penetration Apparatus
Phone Number :
+8615665870097
WhatsApp :
8613805402265
Power 40W Karl Fischer Trace Moisture Meter For Various Oils Power Supply 220V±10% 50Hz
Titration Method: | Electricity Titration(Coulomb Analysis) |
---|---|
Display: | 5.6-inch Color Touch Screen(LCD |
Electrolytic Current Control: | 0~400mA Automatic Control |
Resolution Ration 0.1ug Automatic Trace Moisture Meter Faradaic Current 0~400mA
International Standard: | GB/T7600、GB/T11133 |
---|---|
Precision: | The Test Water Amount Between 10ug ~ 1000ug,the Error Is Less Than 3ug The Test Water Is Less Than 1000ug, And The Error Is Less Than 0.3% |
Measuring Range: | 0.0001% To 100%, According To PPM, From 0.1ppm To 1 Million Ppm |
Measuring Range 3μG~100mg Automatic Grease Trace Moisture Meter Power 40W
Electrolytic Current: | 0~400mA |
---|---|
Measuring Range: | 3μg~100mg |
Distinguish Rate: | 0.1μg |
Automatic Crystallization Point And Cloud Point Analyzer AC220V±10% 50HZ
Working Power Supply: | AC220V ± 10%; 50HZ |
---|---|
Working Cold Bath: | Double-layer Vacuum Glass Bath |
Cold Bath Temperature Control: | -70 ℃ To Room Temperature |
Power 1.5KW Insulating Oil Corrosion Sulfur Tester Power Supply AC220V 50HZ
Implementation Standard: | SH/T0804、SH/T0304、ASTM D1275 |
---|---|
Operating Temperature: | Normal Temperature ~ 200℃ |
Temperature Control Accuracy: | ±1℃ |
Rotation Speed 0.1-200 Brinell Rotational Viscometer Viscosity Range 1-6 Million Mpa
Applicable Standard: | ASTM D2983 GB/T11145 |
---|---|
Temperature Range: | Room Temperature To -40 Degrees Celsius |
Temperature Control Method: | Digital PID Temperature Controller |
Fully Automatic Kinematic Viscometer Apparatus Timing Range 0.0s~9999.9s
Compliant With Standards: | GB/T265、ASTM D445 |
---|---|
Temperature Control Range: | Room Temperature+5 ℃~100.0 ℃ |
Temperature Control Accuracy: | ± 0.1 ℃ |
Automatic Low Temperature Kinematic Viscometer Heating Power 750W
Temperature Control Point: | -40 ℃ -60 ℃ Can Be Set Arbitrarily |
---|---|
Temperature Control Accuracy: | ± 0.1 ℃ |
Measurement Range: | 0.6-17000mm2/s |
Automatic Utterberg Kinematic Viscometer Power 2000W AC220V±10% 50HZ
Working Viscometer: | Ubbelohde Capillary Viscosity Tube |
---|---|
Viscometer Fixture: | Made Of All 304 Stainless Steel Material, With High And Low Temperature Resistant Graphite Sliding Bearing Device |
Measurement Quantity: | 2 Sets |
Maximum Power 2000W Fully Automatic Reverse Flow Viscometer Size 450*380*550
Measurement Quantity: | 2 Sets |
---|---|
Temperature Range: | Room Temperature -100 ℃ |
Temperature Control Accuracy: | ± 0.1 ℃ |