China SH102D Fully automatic constant temperature petroleum density meter with a precision of 0.5% and 1/1000

SH102D Fully automatic constant temperature petroleum density meter with a precision of 0.5% and 1/1000

MODEL: SH102D1
Measurement Range Of Density: 0.0001~1.999g/cm3
Density Measurement Accuracy: ± 0.0005g/cm3
China Principle of Titration Neutralization Method SH108A Fully Automatic Oil Acid Number Meter Essential for Refineries

Principle of Titration Neutralization Method SH108A Fully Automatic Oil Acid Number Meter Essential for Refineries

MODEL: SH108A
Range: 0.001~3.000mgKOH/g
Power Rate: 300 W
China ASTM D974  Gasoline and kerosene acidity detection SH108B reflux automatic acidity tester Automatic titration

ASTM D974 Gasoline and kerosene acidity detection SH108B reflux automatic acidity tester Automatic titration

MODEL: SH108B
Power Supply: AC220V± 20% 50Hz± 10%
Measuring Range: 0.001-2.0mgKOH/g
China Heavy oil and crude oil motion viscometer ASTM D445 manual lofting and automatic judgment 4 holes

Heavy oil and crude oil motion viscometer ASTM D445 manual lofting and automatic judgment 4 holes

MODEL: SH112
Power Supply: AC 220V ± 10%, 50HZ ± 5%
Heating Power: 1800W
China Fully automatic petroleum product pour point tester Single hole SH113E glass test tube automatic tilting method

Fully automatic petroleum product pour point tester Single hole SH113E glass test tube automatic tilting method

MODEL: SH113E
Compliance With Standard: GB/T510
Temperature Range: +30 ℃~-70 ℃
China Principle of Titration Neutralization Method SH108 Oil Acid Number Tester Essential for oil refineries

Principle of Titration Neutralization Method SH108 Oil Acid Number Tester Essential for oil refineries

MODEL: SH108
Power Supply: 220V±10%,50Hz±1%
Ambient Temperature: 10 ℃ ~ +30℃
China Essence and fragrances Determination of flash point SH105E automatic Binsky Martin closed flash point tester

Essence and fragrances Determination of flash point SH105E automatic Binsky Martin closed flash point tester

MODEL: SH105E
Working Power Supply: AC220V ± 10%, 50Hz
Method Of Use: Binsky Martin Closed Cup Method
China SH105D balance method low-temperature closed flash point tester for closed flash point detection of paints and paints

SH105D balance method low-temperature closed flash point tester for closed flash point detection of paints and paints

MODEL: SH105D
Power Supply: AC 220V±10%, 50 Hz
Flash Point Measurement Range: -30~100°C
China Automatic calculation results of SH101C automatic mechanical impurity content analyzer (with balance)

Automatic calculation results of SH101C automatic mechanical impurity content analyzer (with balance)

MODEL: SH101C
Temperature: 4-way PID Temperature Control
Temperature Control Range: Room Temperature~100 ℃
China Mechanical impurity content detection of lubricating oils and additives SH101 gravimetric method

Mechanical impurity content detection of lubricating oils and additives SH101 gravimetric method

MODEL: SH101
Power: AC220V±10% 50Hz
Temperature Control Accuracy: ≤± 1 ℃.
8 9 10 11 12 13 14 15