Chemiluminescence Nitrogen Determination Instrument 0.1 ~ 10000mg/L ASTM D4629
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
x| Measurement Range | 0.1 ~ 10000mg/L | Temp Control Range | RT ~ 1050℃ |
|---|---|---|---|
| Temp Control Accuracy | ±3℃ | Determination Method | Chemiluminescence |
| Sample Types | Liquid, Solid, And Gas | Power Supply | AC220V±22V,50Hz±0.5Hz,1500 W |
| Highlight | Chemiluminescence nitrogen analyzer for lube oil,ASTM D4629 nitrogen testing instrument,High-sensitivity nitrogen determination equipment |
||
SH708 Chemiluminescence Nitrogen Determination Instrument
The SH708 chemiluminescence nitrogen analyzer uses the chemiluminescence method to determine the total nitrogen content, which improves the ability to resist impurity interference and avoids the cumbersome operation of the titration cell caused by the coulometric method and the resulting unstable factors, greatly improving the sensitivity of the instrument. The key components of the system use imported components, ensuring reliable performance of the entire machine. Applicable to the determination of total nitrogen content in paraffin oil, diesel, gasoline, lubricating oil, fuel oil, liquefied gas, and natural gas, as well as other oil products, chemical raw materials, and finished products, in accordance with the standard SH/T 0657 Determination of Trace Nitrogen in Liquid Petroleum Hydrocarbons (Oxidative Combustion and Chemiluminescence Method, ASTM D5762-2017, SH/T 0704, ASTM D4629, GB/T 17674 Determination of Nitrogen Content in Crude Oil by Boat Injection Chemiluminescence Method).
Performance characteristics
● The use of pneumatic support instrument cover, open the instrument cover internal structure at a glance.
● The front shape and repeatability of low and small content are better.
● The instrument can be continuously switched on for 24 hours continuous use of accurate chemiluminescence nitrogen determination instrument.
● The total nitrogen content in the sample was rapidly measured by chemiluminescence method.
● High-precision data acquisition and the application of computer technology provide a reliable guarantee for data acquisition, control and processing.
Technical parameters
| Sample types | liquid, solid, and gas | ||
| Determination method | Chemiluminescence | ||
| Sample injection volume |
Solid sample 1-20mg, Liquid sample 5-20 μ L, Gas sample 1-5mL |
||
| Measurement range | 0.1 ~ 10000mg/L | ||
| Measurement accuracy | |||
| Concentration value (ppm) | Injection volume (μL) | RSD(%) | |
| 0.1 | 20 | 25 | |
| 5 | 10 | 10 | |
| 50 | 10 | 5 | |
| 100 | 10 | 3 | |
| 5000 | 10 | 3 | |
| Temp control range | RT ~ 1050℃ | ||
| Temp control accuracy | ±3℃ | ||
| Air source requirements | High purity argon gas: purity above 99.995% | ||
| High purity oxygen: purity above 99.995% | |||
| Power supply | AC220V±22V,50Hz±0.5Hz,1500 W | ||
| Host size | 305(W)×460(D)×440(H)mm | ||
| Host weight | 20kg | ||
| Temp controlled dimensions | 550(W)×460(D)×440(H)mm | ||
| Temp controlled weight | 40kg | ||
![]()
Note: The appearance pictures, dimensions, volume and weight of the instrument are for reference only. If there are any updates to the instrument, they may be slight changes without prior notice.
Requirements for instrument completeness: host (data acquisition, control system), cracking furnace, automatic sampler (gas, liquid), computer operation software, etc.
Other optional items: computer, solid sampler, gas sampler (optional).
Packing list
| Number | Name | Quantity | Unit | Note |
| 1 | Host | 1 | Unit | |
| 2 | Sampler | 1 | Unit | |
| 3 | Quartz tube | 1 | Piece | |
| 4 | Sample standard | 4 | Box | |
| 5 | Quartz elbow | 1 | Piece | |
| 6 | Membrane dryer | 1 | Piece | Imported from Japan |
| 7 | Communication cable | 1 | Root | |
| 8 | Power cord | 2 | Root | |
| 9 | Cracking furnace power supply | 1 | Root | |
| 10 | Polytetrafluoroethylene | 8 | Meter | Φ3 |
| 11 | Silicone tube | 20 | cm | Φ3 |
| 12 | Silicone tube | 20 | cm | Φ5 |
| 13 | Big clip | 1 | Piece | |
| 14 | Warranty Card Certificate of Conformity | 1 | Piece | |
| 15 | Instruction Manual | 1 | Copy | |
| 16 | Half Moon Ceramic Cup | 4 | Piece | |
| 17 | Injection needle | 2 | Piece | |
| 18 | Fuse tube | 2 | Piece | 2A |
| 19 | Pneumatic pressure cap | 4 | Piece | |
| 20 | Thermocouple | 1 | Piece | S-type platinum rhodium platinum |
| 21 | Sample injection pad | 50 | Piece | |
| 22 | Computer | 1 | Unit | bring your own |
Shandong Shengtai Instrument Co., Ltd. provides the following quality assurance for the instruments sold to you:
----The provided instrument materials are brand new, meet national quality standards, and have a manufacturer's certificate of conformity;
----The materials and main components provided meet the technical requirements specified in the technical documentation;
----The overall quality assurance period of the equipment is one year (excluding normal wear and tear of vulnerable parts).
----We are responsible for free maintenance of any instrument quality issues that occur during the warranty period. Due to equipment malfunction caused by the user's responsibility, we are responsible for repairing and charging reasonable fees.
----Lifetime discounted supply of parts for equipment, and lifetime maintenance and repair of the entire machine.
----After the expiration of the warranty period, if the user needs maintenance and technical services, we will only charge a cost fee.