Petroleum Testing Instruments
-
Lubricating Oil And Grease Antifreeze Testing Instruments
-
Diesel Fuel Testing Equipment
-
Transformer Oil Testing Equipment
-
Feed Testing Instrument
-
Pharmaceutical Testing Instruments
-
Edible Oil Testing Equipment
-
Chemical Analysis Instruments
-
Lube Oil Testing Equipment
-
Flour Test Instrument
-
Food Testing Instruments
-
Crude Oil Testing Equipment
-
Hydraulic Oil Testing Equipment
-
Flash Point Tester
-
Kinematic Viscosity Tester
-
Freezing Point Tester
-
Cone Penetration Apparatus
Light Petroleum Sulfur And Chlorine Analyzer S 0.1 ~ 10000mg/L Coulombic Mode ASTM D3120
| Place of Origin | CHINA |
|---|---|
| Brand Name | Shandong Shengtai Instrument Co.,Ltd |
| Certification | SH/T 0253 GB/T 11061 SH/T 0222 SH/T 0254 GB/T 6324.4 ASTM D3246 ASTM D3120 |
| Model Number | SH409 |
| Minimum Order Quantity | 1 |
| Packaging Details | wooden crate |
| Delivery Time | 7 - 15 work days |
| Payment Terms | T/T |
| Supply Ability | 10000 sets / year |
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
x| S Measurement Range | 0.1mg/L ~ 10000mg/L | Cl Measurement Range | 0.2mg/L ~ 10000mg/L |
|---|---|---|---|
| Lower Limit Of Detection | S: 0.1mg/L Cl: 0.2mg/L | Temp Control Range | RT ~ 1000 ℃ |
| Cooling Method | Air Cooling | Temp Control Accuracy | ± 2℃ |
| Host Dimensions | 530 * 430 * 330mm | Sample Injector Dimensions | 350 * 130 * 140mm |
| Highlight | Light Petroleum Sulfur Analyzer ASTM D3120,Chlorine Analyzer Coulombic Mode,Lube Oil Testing Equipment with Warranty |
||
SH409 Petroleum product sulfur and chlorine analyzer (Coulombic method)
The SH409 petroleum product sulfur and chlorine analyzer applies microcoulometry analysis technology, uses oxidation method to oxidize the sample into titratable ions through a cracking furnace, titrates in a titration cell, and calculates the sulfur or chlorine content in the sample based on the electricity consumption during the electrolytic titration process and Faraday's law. Widely used for detecting sulfur and chlorine content in liquid, solid, or gas samples. The microcomputer sulfur and chlorine analyzer meets the standards of SH/T 0253, GB/T 11061, SH/T 0222, SH/T 0254, and GB/T6324.4.
Performance characteristics
● The instrument adopts air cooling for heat dissipation, the fan automatically switches on and off, and no one needs to be on duty to shut down and cool down!
● The instrument adopts an independent temperature control system. Using Yudian's fully automatic temperature controller, the failure rate is close to zero.
● Windows operating platform, direct human-machine dialogue.
● The computer controls the entire analysis, data processing, and other processes, displaying the working status and data peaks of the entire process. Parameters, data, and peaks can be saved or printed as needed.
● The instrument adopts internationally popular circuits and imported components, reducing instrument noise and improving detection sensitivity.
● Accurate and stable instrument measurement results.
Instrument execution standards
● SH/T 0253-92 Standard for determination of total sulfur content in light petroleum products using the coulometric method
● GB/T 11061-1997 Determination of total sulfur in natural gas - standard for oxidation microcoulometry method
● SH/T 0222-1992 Standard for Determination of Total Sulfur Content in Liquefied Petroleum Gas (Electricity Method)
● GB/T6324.4 Organic liquid chemical products - Determination of trace sulfur - Microcoulombic method
● SH/T 0254, ASTM D3120,ASTM D3246
Technical parameters
| Measurement range |
S: 0.1mg/L ~ 10000mg/L Cl: 0.2mg/L ~ 10000mg/L |
| Lower limit of detection | S: 0.1mg/L Cl: 0.2mg/L |
| Repeatability error |
x≤0.5mg L<30% 0.5mgL<x≤1.0mg L<10% 1.0mgl <x≤10mg L<8% x>10mg L<4% |
| Temp control range | RT ~ 1000 ℃ |
| Temp control accuracy | ± 2℃ |
| Cooling method | air cooling |
| Measurable sample status | solid, gas (with corresponding injector) |
| Bias voltage range | 0-596mv |
| Power | 3.5KW |
| Host dimensions | 530 * 430 * 330mm |
| Sample injector dimensions | 350 * 130 * 140mm |
![]()
Note: The appearance pictures, dimensions, volume and weight of the instrument are for reference only. If there are any updates to the instrument, they may be slight changes without prior notice.
Users need to provide equipment:
● One bottle of regular oxygen and one bottle of regular nitrogen (including pressure reducing valve)
● Experimental bench (not less than 50cm * 200cm)
● 20A socket (not less than 3KW)
● 2L pure water, 500mL glacial acetic acid (GR)
● Sulfur is equipped with a sulfur electrolysis cell and a sulfur quartz tube
● Chlorine is configured with a chlorine electrolysis cell and a chloroquartz tube
Packing list
| S/N | Name | Unit | Quantity | Remarks |
| 1 | Host | Set | 1 | Temperature flow controller and host |
| 2 | Stirrer | Set | 1 | |
| 3 | Small clip | Piece | 1 | |
| 4 | Syringe | Piece | 2 | |
| 5 | 10ul Silicone pad | Piece | 30 | |
| 6 | Φ5 Silicone tube | cm | 50 | |
| 7 | Φ9 Silicone tube | cm | 50 | |
| 8 | Polytetrafluoroethylene tube | m | 8 | Φ3 |
| 9 | Thermocouple K | Piece | 2 | Equipped with instrument |
| 10 | Power cord | Root | 3 | |
| 11 | Connection line | Piece | 1 | |
| 12 | Electrolytic cell | Piece | 1 | |
| 13 | Quartz tube | Piece | 1 | |
| 14 | User manual | Copy | 1 | |
| 15 | Warranty Card Certificate | Copy | 1 | |
| 16 | 2A fuse | Piece | 2 | |
| 17 | Cracking furnace power line | Piece | 1 | |
| 18 | Standard sample | Box | 3 | Sulfur |
| 19 | Sampler | Set | 1 | |
| 20 | Computer | Set | 1 | Self provided |
![]()
Shandong Shengtai Instrument Co., Ltd. provides the following quality assurance for the instruments sold to you:
----The provided instrument materials are brand new, meet national quality standards, and have a manufacturer's certificate of conformity;
----The materials and main components provided meet the technical requirements specified in the technical documentation;
----The overall quality assurance period of the equipment is one year (excluding normal wear and tear of vulnerable parts).
----We are responsible for free maintenance of any instrument quality issues that occur during the warranty period. Due to equipment malfunction caused by the user's responsibility, we are responsible for repairing and charging reasonable fees.
----Lifetime discounted supply of parts for equipment, and lifetime maintenance and repair of the entire machine.
----After the expiration of the warranty period, if the user needs maintenance and technical services, we will only charge a cost fee.