Automatic Flash Andignition Point Tester RT ~ 400℃ Electronic Ihnition COC Method ASTM D92
Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
x| Temp Measure Range | RT ~ 400℃ | Resolution | 0.1℃ |
|---|---|---|---|
| Ignition Method | Electronic Ihnition | Gas Flame | 3mm ~ 4mm |
| Environment Temp | 10 ~ 40℃ | Relative Humidity | ≤ 80% |
| Highlight | Automatic flash point tester ASTM D92,Electronic ignition COC method tester,Lube oil testing equipment RT 400℃ |
||
SH106BR Fully automatic open flash andignition point tester
The SH106BR Automatic Open Flash Point and Andignition Point Tester is designed and manufactured in accordance with the requirements specified in the People's Republic of China standard GB/T 3536, ASTM D92 "Petroleum Products - Determination of Flash Point and Flash Point (Cleveland Open Cup Method)" and GB/T267-1988, ASTM D92 Petroleum Products - Determination of Flash Point and Flash Point (Open Cup Method).
Standard: GB/T 3536 ASTM D92 GB/T267 ISO 2592
Open flash point testers are mostly used for lubricating oils and heavy petroleum products, because when measured with this product, the vapor formed by heating petroleum products continuously diffuses into the surrounding air, resulting in a higher measured flash point. For most lubricating oils and heavy oils, especially when used in unsealed parts or at low temperatures, even a small amount of light admixtures will evaporate during use, without posing a risk of ignition or explosion. Therefore, these products are measured using an open flash point tester.
Main technical features
● Adopts a large color LCD screen display, a full Chinese human-computer dialogue interface, and an unmarked keyboard. It has a prompt menu and guided input function for parameters such as predictable temperature, sample label, atmospheric pressure, and test date.
● Simulate and track the function curve between temperature rise and test time, with Chinese misoperation software prompt modification function, and parameter prompt functions such as test date and time.
● Automatically correct the effect of atmospheric pressure on the test and calculate the correction value.
● Differential detection, automatic correction of system deviation.
● Scanning, detecting, and printing data are automatically completed, and the test arm automatically rises and falls.
● Electronic ignition, forced air cooling
● Automatic ignition without the need for a gas source improves the safety of the test
Main technical parameters
| Power supply | AC220V±10% 50HZ |
| Temp measure range | RT ~ 400℃ |
| Repeatability |
Flash point ≤ 150℃, Error ± 2 ℃; Flash point ≥ 150℃, Error ± 3 ℃; |
| Resolution | 0.1℃ |
| Accuracy | 0.5% |
| Heating speed | Comply with GB/T3536 |
| Ignition method | Electronic ihnition |
| Gas flame | 3mm ~ 4mm |
| Environment temp | 10 ~ 40℃ |
| Relative humidity | ≤ 80% |
Note: The appearance pictures, dimensions, volume and weiht of the instrument are for reference only. If there are any updates to the instrument, they may be slight changes without prior notice.
![]()
Packing list
| S/N | Name | Quantity | Unit | Remarks |
| 1 | Automatic opening flash point igniter | 1 | Unit | |
| 2 | Oil cup | 1 | Piece | |
| 3 | AC power cord | 1 | Root | |
| 4 | Printing paper | 1 | Roll | |
| 5 | Operating instruction | 1 | Piece | |
| 6 | Packing list | 1 | Copy | |
| 7 | Certificate of approval | 1 | Copy |
Shandong Shengtai Instrument Co., Ltd. provides the following quality assurance for the instruments sold to you:
----The provided instrument materials are brand new, meet national quality standards, and have a manufacturer's certificate of conformity;
----The materials and main components provided meet the technical requirements specified in the technical documentation;
----The overall quality assurance period of the equipment is one year (excluding normal wear and tear of vulnerable parts).
----We are responsible for free maintenance of any instrument quality issues that occur during the warranty period. Due to equipment malfunction caused by the user's responsibility, we are responsible for repairing and charging reasonable fees.
----Lifetime discounted supply of parts for equipment, and lifetime maintenance and repair of the entire machine.
----After the expiration of the warranty period, if the user needs maintenance and technical services, we will only charge a cost fee.