Automatic Karl Fischer Volumetric Moisture Analyzer RSD ≤ 1.0% Average Time 3 Min
Polarization Voltage: | 0-2499 Mv |
---|---|
Moisture Content Measurement Range: | 0.001% -100% |
Titration Control Accuracy: | 0.005 Ml |
Sensitivity 10-6A Automatic Karl Fischer Volumetric Moisture Analyzer ST-610A
Measurement Range: | 30ppm-100% (H2O Mass Fraction) |
---|---|
Resolution: | 0.01ml |
Repeatability Of Water Titration: | ≤ 0.01 |
Drug Rotation Spectrophotometer Touch Screen CHP 0621 Temp Control 15℃-35℃
Measurement Range: | Optical Rotation ± 89.99 ° |
---|---|
Measurement Accuracy: | ± 0.01 ° (-45 ° ≤ Optical Rotation ≤+45 °) |
Temperature Control Range: | 15 ℃ -35 ℃ |
CHP 0621 Thermostatic Drug Polarimeter ST302 Range - 45°~+45° Water Bath 10-40 ℃
Measurement Range: | - 45°~+45° |
---|---|
Minimum Reading Value: | 0.001° |
Constant Temperature Water Bath: | 10-40 ℃ |
Capacity 250L Drug Stability Test Chamber Temp Control Range 0-65 ℃ Touch Screen
Internal Volume: | 250L (other Volumes Can Be Customized) |
---|---|
Temp Control Range: | 0-65 ℃ |
Temp Control Fluctuation: | ± 0.5 ℃ |
Resolution 0.1N Fully Automatic Tablet Hardness Tester Measure DIA 2-20mm Microprinter
Measurement Pressure: | 10N-400N (1kg-40kg) |
---|---|
Measuring Diameter: | 2-20mm |
Measurement Accuracy: | ± 0.1% |
Touch Screen Automatic Drug Relative Density Meter Range 0.001-1.999g/Cm3 CHP 0601
Density Resolution: | 0.001g/cm3 |
---|---|
Repeatability: | ± 0.1 ℃ |
Accuracy: | ± 0.001g/cm3 |
80 Data Storage Automatic Drug Relative Density Meter Range 0.001~1.999g/Cm3 ChP 0601
Measurement Range Of Density: | 0.001~1.999g/cm3 |
---|---|
Density Measurement Accuracy: | ± 0.001g/cm3 |
Density Resolution: | ± 0.001g/cm3 |
0.86N.M Torque Digital Vibrating Density Meter Sample Volume ≤250ml ISO3953 1993
Weight Of The Tested Sample: | ≤ 500.00g |
---|---|
Volume Of Compacted Sample: | ≤ 250ml |
Single Vibration Frequency: | ≤ 0~99999 Times (when Set To 0 Times, The Output Is "loose Packing Density") |
500g Sample Automatic Compaction Density Meter 0~300rpm Continuing Adjust GB/T 5162-2020
Display Mode: | Touch Screen Display |
---|---|
Testing Station: | 1/2/3 |
Repetitive Error: | ≤ 1% |