Gasoline Test Kit Fully Automatic Oxidation Stability Analyzer 0 ~ 1600 KPa PT100 Sensor ASTM D525
| Oxygen Bomb Pressure Transmitter Measurement Range | 0 ~ 1600 KPa | Measurement Accuracy | ±2‰ |
|---|---|---|---|
| Bath Temp Control Point | Metal Bath Heating At 100.0°C ± 0.1°C | Temp Measurement Element | Platinum Resistance PT100, ±0.1°C |
| Ambient Temperature | ≤30℃ | Relative Humidity | ≤85% |
| Highlight | Gasoline test kit oxidation stability analyzer,Automatic gasoline oxidation analyzer PT100 sensor,Gasoline stability tester ASTM D525 compliant |
||
SH8018 Automatic gasoline oxidation stability tester (induction period method)
ASTM D525 Induction Period Method Automatic Gasoline Oxidation Stability Tester
Gasoline Test Kit Fully Automatic Oxidation Stability Analyzer ASTM D525
Induction Period Method Oxidation Stability Tester
Induction Period Method ASTM D525 Automatic Oxidation Stability Bath of Gasoline
Gasoline Oxidation Stability Tester with Induction Period Method
ASTM D525 Oxidation Stability Test Machine (Induction Period Method)
Standard: GB/T 8018 ASTM D525
SH8018 Automatic Gasoline Oxidation Stability Tester is designed and manufactured in accordance with the requirements specified in the Chinese National Standard GB/T 8018-2015 "Method for Determination of Oxidation Stability of Gasoline (Induction Period Method)" and also complies with the ASTM D525 standard.
Applicable for determining the oxidative stability of gasoline under accelerated oxidation conditions in accordance with the GB/T 8018 standard. Equipped with a color LCD screen, it can display real-time temperature and pressure curves of the test sample. Users can adjust the sample pressure or modify the instrument time in real time. Designed with an embedded system, it allows users to view historical data and print results using the built-in printer. Suitable for products such as automotive gasoline, ethanol-blended automotive fuel components, and ethanol-blended automotive gasoline
Key Technical Indicators and Parameters
| Oxygen bomb pressure transmitter measurement range | 0 ~ 1600 kPa |
| Measurement accuracy | ±2‰ |
| Bath temp control point | Metal bath heating at 100.0°C ± 0.1°C |
| Temp measurement element | Platinum resistance PT100, ±0.1°C |
| Heating tube power | 1800W |
| Ambient temperature | ≤30℃ |
| Relative humidity | ≤85% |
| Operating power supply | AC220V±5% 50Hz |
| Dimensions | 660*400*350mm |
| Weight | 40kg |
| Packaging dimensions | 530*470*555mm (L*W*H) |
| Packaging weight | 22.9kg carton |
![]()
● Storage method: Experimental results can store up to 199 sets of historical data for easy retrieval;
● Result Output: Equipped with USB flash drive output functionality, allowing data to be transferred to a PC for long-term storage
● Output Format: The results on the USB drive should be in CSV or Excel format.
★ Remote Upgrade: Equipped with TCP network transmission capability, enabling remote software upgrades in later stages (optional)
★ Data Management: Compatible with LIMS systems (optional)
Note: The appearance images, dimensions, volume, and weight of the instrument are for reference only. Minor changes may occur if the instrument is updated, and no separate notice will be provided.
Instrument Quality Assurance Certificate
Shandong Shengtai Instrument Co., Ltd. provides the following quality assurance for the instruments sold to you:
----The provided instrument materials are brand new, meet quality standards, and have a manufacturer's certificate of conformity;
----The materials and main components provided meet the technical requirements specified in the technical documentation;
----The overall quality assurance period of the equipment is one year (excluding normal wear and tear of vulnerable parts).
----We are responsible for free maintenance of any instrument quality issues that occur during the warranty period. Due to equipment malfunction caused by the user's responsibility, we are responsible for repairing and charging reasonable fees.
----Lifetime discounted supply of parts for equipment, and lifetime maintenance and repair of the entire machine.
----After the expiration of the warranty period, if the user needs maintenance and technical services, we will only charge a cost fee.
Packaging and Delivery
1. Packaging of goods: standard wooden or cardboard boxes.
2. Internal packaging: Elastic pearl cotton packaging product, hardwood board+strong bandage to fix corners.
![]()
Packing list
| S/N | Name | Unit | Quantity | Remarks |
| 1 | Host | Set | 1 | |
| 2 | Test oxygen bomb assembly | Set | 2 | |
| 3 | Special glass mercury thermometer for induction period | Piece | 1 | |
| 4 | Glass test bottle and cap | Set | 2 | |
| 5 | Instruction | Copy | 1 | |
| 6 | Packing list | Copy | 1 | |
| 7 | Certificate warranty card | Copy | 1 |