ASTMD 6371 Cold Filter Plugging Point Solidification Point Tester -68 ~ 30°C Single Hole

Place of Origin CHINA
Brand Name Shandong Shengtai Instrument Co., Ltd.
Certification GB/T510 SH/T 0248 ASTM D 6371
Model Number SH0248C
Minimum Order Quantity 1
Packaging Details wooden ceate
Delivery Time 7 - 15 work days
Payment Terms T/T
Supply Ability 10000 sets / year
Product Details
Temp Measurement Range -68 ~ 30°C Resolution 0.1°C
Pressure Measurement Range 200mmH2O±1mmH2O Number Of Test Samples 1 Channel
Instrument Dimensions 650*480*620mm Instrument Weight 75kg
Highlight

ASTMD 6371 solidification point tester

,

single hole cold filter plugging tester

,

transformer oil solidification point equipment

Leave a Message
Product Description

SH0248C Automatic Diesel Solidifying point cold filter point tester

Standard: GB/T510 SH/T 0248 ASTM D 6371

The SH0248C Fully Automatic Cold Filter Point and Pour Point Tester is based on the national standards GB/T 510 "Determination of Pour Point of Petroleum Products" and SH/T 0248. Utilizing advanced contemporary technology, it integrates mechanical, optical, electronic, and computer technologies to automatically perform tests for the pour point and cold filter point of petroleum products. The instrument employs photoelectric detection technology, an automatic glass tube tilting method, and an imported compressor-based cooling system to ensure the required cooling depth.

Instrument features:

● Embedded system design, imported PT100 temperature sensors, automatic detection throughout the entire testing process;

● 7-inch TFT Touch Color LCD Display

● Storage Method: The experimental results can store up to 199 sets of historical data for easy retrieval;

● Result Output: Equipped with USB flash drive output functionality, enabling long-term storage on PC

● Output Format: The result USB output format should be CSV or Excel

● Standard printing: Standard mini printer, automatic measurement, automatic thermal printing

★ Remote Upgrade: Equipped with TCP network transmission capability, allowing for software remote upgrades in later stages (optional)

★ Data Management: Compatible with LIMS system (optional)

● After the test is completed, if no manual operation is required, the refrigeration unit can be set to automatically shut down within 0-50 minutes to prevent frequent compressor activation and extend the instrument's service life

Technical specifications

Standards GB/T 510 SH/T 0248 ASTM D 6371
Temp measurement range -68 ~ 30°C
Resolution 0.1°C
Pressure measurement range 200mmH2O±1mmH2O
Number of test samples 1 channel
Temp measurement element PT100
Detection method Top-mounted photoelectric detector
Refrigeration method Imported cascade compression refrigeration
Cooling method Air-cooled
Printing 20-column Chinese dot matrix printing
Display 128×64 Chinese character display
Instrument dimensions 650*480*620mm
Instrument weight 75kg
Packaging dimensions 690*520*660mm
Packaging weight 80kg

ASTMD 6371 Cold Filter Plugging Point Solidification Point Tester -68 ~ 30°C Single Hole 0

Note: The appearance pictures, dimensions, volume and weight of the instrument are for reference only. If there are any updates to the instrumemnt, they may be slight changes without prior notice.

 

Instrument Quality Assurance Certificate

Shandong Shengtai Instrument Co., Ltd. provides the following quality assurance for the instruments sold to you:

----The provided instrument materials are brand new, meet quality standards, and have a manufacturer's certificate of conformity;

----The materials and main components provided meet the technical requirements specified in the technical documentation;

----The overall quality assurance period of the equipment is one year (excluding normal wear and tear of vulnerable parts).

----We are responsible for free maintenance of any instrument quality issues that occur during the warranty period. Due to equipment malfunction caused by the user's responsibility, we are responsible for repairing and charging reasonable fees.

----Lifetime discounted supply of parts for equipment, and lifetime maintenance and repair of the entire machine.

----After the expiration of the warranty period, if the user needs maintenance and technical services, we will only charge a cost fee.

 

Packaging and Delivery

1. Goods packaging: standard wooden or cardboard boxes.

2. Internal packaging: Elastic pearl cotton packaging product, hardwood board+strong bandage to fix corners.

 

Packing list

S/N Name Unit Quantity Remarks
1 Automatic cold filter point tester Set 1  
2 Cold filtration point suction filtration device Set 1  
3 Cold filter point test tube Piece 1  
4 Pipette Piece 1  
5 Suction head assembly Set 1 Brass housing, nut, strainer, etc
6 Freezing point test tube Set 1  
7 Condensation point sensor Set 1  
8 Plastic tie Piece Some  
9 Silicone tube left and right Piece 1  
10 Fuse Piece 1 L*W: 100 * 2mm
11 Power cord Piece 1  
12 Instruction Copy 1  
13 packing list Copy 1  
14 Certificate warranty card Copy 1  

ASTMD 6371 Cold Filter Plugging Point Solidification Point Tester -68 ~ 30°C Single Hole 1