Petroleum Testing Instruments
-
Lubricating Oil And Grease Antifreeze Testing Instruments
-
Diesel Fuel Testing Equipment
-
Transformer Oil Testing Equipment
-
Feed Testing Instrument
-
Pharmaceutical Testing Instruments
-
Edible Oil Testing Equipment
-
Chemical Analysis Instruments
-
Lube Oil Testing Equipment
-
Flour Test Instrument
-
Food Testing Instruments
-
Crude Oil Testing Equipment
-
Hydraulic Oil Testing Equipment
-
Flash Point Tester
-
Kinematic Viscosity Tester
-
Freezing Point Tester
-
Cone Penetration Apparatus
ASTM D2274 Distillate Fuel Oil Oxidation Stability Tester 4 Channels RT ~ 200℃
| Flow Meter | 50ml/min+5ml/min, Each Oxidation Tube Is Connected With A Flowmeter | Oxygen Tube | Special High Temperature Resistant Glass Products |
|---|---|---|---|
| Temp Control Range | RT ~ 200℃ | Temp Control Accuracy | Setting Temp ±0.1℃ |
| Temp Measurement Element | Thermal Resistance | Working Power Supply | AC220V 50HZ |
| Highlight | ASTM D2274 fuel oil stability tester,distillate fuel oxidation tester 4 channels,diesel fuel testing equipment with warranty |
||
SH0175 Distillate fuel oil oxidation stability tester
SH0175 distillate fuel oil oxidation stability instrument is designed and manufactured according to the requirements stipulated in the People's Republic of China industry standard SH/T 0175 "distillate fuel oil oxidation stability determination method (acceleration method)".
It is suitable for the determination of intrinsic stability of intermediate distillate fuel oil by accelerated oxidation method according to the method specified in SH/T 0175 standard.This instrument is the oil production, production, use units, the relevant universities, scientific research departments and other test distillate fuel oil oxidation stability performance of a preferred automatic instrument.
Main performance
● The instrument is equipped with a temperature control meter to regulate the water bath temperature at 95°C ± 0.2°C. Users can also adjust the temperature control meter according to actual needs.
● The instrument's workbench is equipped with four test baths, enabling simultaneous testing of four specimens.
● The instrument is equipped with four flow meters, each indicating the gas flow rate into one of the four oxidation tubes. The oxygen source used by the instrument must have a purity of no less than 99.5%, and it can be directly connected from an oxygen cylinder. If the oxygen is sourced from the factory's main oxygen pipeline, a filter and pressure regulator should be installed before connecting to the instrument. The oxygen input port is located on the side of the instrument.
● The instrument is equipped with a timer to record the test duration, with an alarm alert when the time is up.
● The instrument is equipped with a dark box for light-protected storage before placing the oxidation tubes into the heating bath and for light-protected cooling after removing them.
Main technical indicators
| Flow meter | 50ml/min+5ml/min, each oxidation tube is connected with a flowmeter |
| Oxygen tube | special high temperature resistant glass products |
| Working power supply | AC220V 50HZ |
| Power consumption | ≤2400W |
| Temp control mode | digital display temp control meter automatic temp control |
| Temp control range | RT ~ 200℃ |
| Temp control accuracy | setting temp ±0.1℃ |
| Temp measurement element | thermal resistance |
| The number of samples | 4, at the same time can be used for 4 samples |
| Instrument size | 520*420*510mm |
| Instrument weight | 35kg |
![]()
Note: The appearance pictures, dimensions, volume and weight of the instrument are for reference only. If there are any updates to the instrument, they may be slight changes without prior notice.
Instrument Quality Assurance Certificate
Shandong Shengtai Instrument Co., Ltd. provides the following quality assurance for the instruments sold to you:
----The provided instrument materials are brand new, meet quality standards, and have a manufacturer's certificate of conformity;
----The materials and main components provided meet the technical requirements specified in the technical documentation;
----The overall quality assurance period of the equipment is one year (excluding normal wear and tear of vulnerable parts).
----We are responsible for free maintenance of any instrument quality issues that occur during the warranty period. Due to equipment malfunction caused by the user's responsibility, we are responsible for repairing and charging reasonable fees.
----Lifetime discounted supply of parts for equipment, and lifetime maintenance and repair of the entire machine.
----After the expiration of the warranty period, if the user needs maintenance and technical services, we will only charge a cost fee.
Packaging and Delivery
1. Goods packaging: standard wooden or cardboard boxes.
2. Internal packaging: Elastic pearl cotton packaging product, hardwood board+strong bandage to fix corners.
Packing list
| S/N | Name | Quantity | Unit | Remarks |
| 1 | Distillate fuel oil oxidation stability tester host | 1 | Set | |
| 2 | Equipped with black box | 1 | Set | |
| 3 | Oxidation tube | 4 | Piece | |
| 4 | condenser | 4 | Piece | |
| 5 | Oxygen tube | 4 | Piece | |
| 6 | Bath cover | 4 | Piece | |
| 7 | Hose (inside diameter φ 6) | 4 | Piece | Flowmeter outlet to glass oxygen pipe - 50 mm/piece |
| 8 | Hose (inside diameter φ 6) | 1 | Meter | For water inlet and outlet of glass condensate pipe, the length of each section shall be cut as required |
| 9 | Power cord | 1 | Copy | |
| 10 | Instruction | 1 | Copy | |
| 11 | Packing list | 1 | Copy | |
| 12 | Certificate warranty card | 1 | Copy |
![]()