Petroleum Testing Instruments
-
Lubricating Oil And Grease Antifreeze Testing Instruments
-
Diesel Fuel Testing Equipment
-
Transformer Oil Testing Equipment
-
Feed Testing Instrument
-
Pharmaceutical Testing Instruments
-
Edible Oil Testing Equipment
-
Chemical Analysis Instruments
-
Lube Oil Testing Equipment
-
Flour Test Instrument
-
Food Testing Instruments
-
Crude Oil Testing Equipment
-
Hydraulic Oil Testing Equipment
-
Flash Point Tester
-
Kinematic Viscosity Tester
-
Freezing Point Tester
-
Cone Penetration Apparatus
Initial Adhesion Tester Table Width 120mm Steel Ball 1/32 Inch ~ 1 Inch ASTM D3121
| Adjustable Tilt Angle | 0 ~ 60° | Table Width | 120 Mm |
|---|---|---|---|
| Test Area Width | 80 Mm | Standard Steel Ball | 1/32 Inch ~ 1 Inch |
| Instrument Size | 380*150*170 Mm | Instrument Weight | 4.15kg |
| Highlight | adhesion tester table 120mm width,steel ball adhesion tester ASTM D3121,pharmaceutical adhesion tester 1/32 inch |
||
ST106 Initial adhesion tester
The ST106 initial adhesion tester, also known as the initial adhesion tester or tape adhesion tester, is designed and manufactured in accordance with the requirements of the new version of the 2020 Chinese Pharmacopoeia "0952 Adhesion Force Determination Method". The equipment adopts the inclined rolling ball method. When a small pressure occurs between the steel ball and the adhesive surface of the test sample, the adhesive tape, label, and other products are used to test the initial adhesion of the sample to the steel ball.
Suitable for conducting initial adhesion testing on pressure-sensitive tapes, medical patches, self-adhesive labels, protective films, and other related products. The initial adhesion tester for labels follows the GB/T 4852 "Test Method for Initial Adhesion of Pressure Sensitive Adhesive Tape - Rolling Ball Method" standard, using the principle of inclined rolling ball method to characterize the initial adhesion performance of adhesive products by the maximum number of steel balls that can be adhered.
Standard: GB/T 4852 ChP 0952 ASTM D3121 JIS Z0237
Testing Principles
Roll a steel ball over the adhesive tape adhesive surface placed flat on an inclined plate, and evaluate its initial viscosity based on the maximum size of the steel ball that can be adhered to by the adhesive surface of the specified length; Alternatively, a steel ball of a specified size can be rolled over an inclined groove and its initial viscosity can be evaluated by measuring its rolling distance on the adhesive surface of the adhesive tape on a horizontal plate.
Using the inclined rolling ball method, the initial adhesion of the sample is tested by the adhesive tape's adhesion to the steel ball when there is a brief contact between the adhesive surface of the steel ball and the pressure-sensitive tape under slight pressure.
Equipment features
● Using the testing principle of inclined rolling ball method, the instantaneous adhesion performance of the sample is tested.
● The test steel balls are designed completely in accordance with national standards, ensuring high accuracy of test data.
● The tilt angle of the test can be freely adjusted according to the user's needs
Execution standards
2020 Chinese Pharmacopoeia 0952 Adhesion Determination Method, GB/T 4852, JIS Z0237
Technical parameter
| Adjustable tilt angle | 0 ~ 60° |
| Table width | 120 mm |
| Test area width | 80 mm |
| Standard steel ball | 1/32 inch ~ 1 inch |
| Instrument size | 380*150*170 mm |
| Instrument weight | 4.15kg |
| Package size | 420*250*230mm |
| Package weight | 6.85kg |
![]()
Standard Configuration
Host, one box of 1-32 standard steel balls
Note: The appearance pictures, volume and weight of the instrument are for reference only. If there are any updates to the instrument, they may be slight changes without prior notice.
Shandong Shengtai Instrument Co., Ltd. provides the following quality assurance for the instruments sold to you:
----The provided instrument materials are brand new, meet national quality standards, and have a manufacturer's certificate of conformity;
----The materials and main components provided meet the technical requirements specified in the technical documentation;
----The overall quality assurance period of the equipment is one year (excluding normal wear and tear of vulnerable parts).
----We are responsible for free maintenance of any instrument quality issues that occur during the warranty period. Due to equipment malfunction caused by the user's responsibility, we are responsible for repairing and charging reasonable fees.
----Lifetime discounted supply of parts for equipment, and lifetime maintenance and repair of the entire machine.
----After the expiration of the warranty period, if the user needs maintenance and technical services, we will only charge a cost fee.