Petroleum Testing Instruments
-
Lubricating Oil And Grease Antifreeze Testing Instruments
-
Diesel Fuel Testing Equipment
-
Transformer Oil Testing Equipment
-
Feed Testing Instrument
-
Pharmaceutical Testing Instruments
-
Edible Oil Testing Equipment
-
Chemical Analysis Instruments
-
Lube Oil Testing Equipment
-
Flour Test Instrument
-
Food Testing Instruments
-
Crude Oil Testing Equipment
-
Hydraulic Oil Testing Equipment
-
Flash Point Tester
-
Kinematic Viscosity Tester
-
Freezing Point Tester
-
Cone Penetration Apparatus
Automatic Fatty Acid Freezing Point Analyzer Animal Oil Fatty - 30℃~+80℃ ASTM D5665

Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xWorking Cold Bath | Double-layer Vacuum Glass Bath | Cold Bath Temperature Control | - 20℃~100℃ |
---|---|---|---|
Temperature Measurement Range | - 30℃~+80℃ | Temperature Sensor | PT100 Imported Temperature Sensor |
Environmental Temperature | ≤ 30 ℃ | Working Power Supply | AC220V±10% 50Hz |
Highlight | Automatic fatty acid freezing point analyzer,Animal oil fatty acid tester,Fatty acid analyzer with ASTM D5665 |
ST-016 Automatic Animal Oil Fatty Acid Freezing Point Analyzer
Overview:
St-016 automatic fat fatty acid freezing point tester is designed and manufactured according to sn/t0801.17 determination of freezing point of fatty acids in imported and exported animal fats and oils and the determination method of fat and fatty oil in Chinese pharmacopoeia in 2025. It is suitable for determining the freezing point of fatty acids in animal fats and oils.
SN/T0801.17 ChP 0713 ISO 935 ASTM D5665
Technical Parameter:
Power supply | AC220V±10% 50Hz |
Working cold bath | double vacuum glass bath |
Cold bath temp control | - 20℃~100℃ |
Temp measurement range | - 30℃~+80℃ |
Temp sensor | PT100 imported temp sensor |
Temp control accuracy | ± 0.1 ℃ |
Environmental temp | ≤ 30 ℃ |
Relative humidity | ≤ 85% |
Whole power | About 1500W |
● Working power supply: AC220V±10%;50Hz
● Working cold bath: double-layer vacuum glass bath
● Cold bath temperature control: - 20℃~100℃
● Temperature measurement range: - 30℃~+80℃
● Temperature sensor: PT100 imported temperature sensor
● Temperature control accuracy: ± 0.1 ℃
● Storage method: The experimental results can store 199 sets of historical data for easy retrieval;
● Result output: It can also be equipped with a USB drive output function to output to the PC for long-term storage
Output format: The output format of the result USB drive is CSV or Excel.
● Data Management: Can be connected to the LIMS system (optional)
● Account management: Audit tracking account hierarchical management, 3-level permission management (optional).
● Data protection: equipped with date and password setting function.
● Standard printing: Standard micro printer with automatic measurement and needle printing
● Data extension: Laser printer interface, can be connected to HP1108 laser printer (optional)
● Remote upgrade: Equipped with TCP network transmission function, software can be remotely upgraded later
● Data memory: The memory of the microcomputer instrument can be expanded to 16GB.
● Bath liquid stirring: The stirring motor automatically stirs, with a power of 6W and a speed of 1200r/min.
● Refrigeration system: imported refrigeration compressor.
● Sample mixing: synchronous reduction motor, once per second.
● Environmental temperature: ≤ 30 ℃
● Relative humidity: ≤ 85%.
● Whole power: About 1500W.
Note: The appearance pictures, dimensions, volume, and weight of the instrument are for reference only. If there are any updates to the instrument, there may be slight changes without prior notice.
Shandong Shengtai Instrument Co., Ltd. provides the following quality assurance for the instruments sold to you:
----The instruments and materials provided are brand-new goods that meet the national quality standards and have the manufacturer's certificate;
----The materials and main components provided meet the technical requirements specified in the technical data;
----The warranty period of the whole equipment is one year (excluding normal wear of wearing parts).
----We are responsible for free maintenance of instrument quality problems during the warranty period. Due to the equipment failure caused by the user's responsibility, we are responsible for the maintenance and reasonable charges.
----.
----After the expiration of the warranty period, when the user needs maintenance and technical services, we only charge the cost.