Fully Automatic Open Flash Point And Ignition Point Tester ASTMD92 Accuracy 0.5%

Place of Origin CHINA
Brand Name Shandong Shengtai Instruments Co., Ltd
Certification GB/T 3536 ASTMD92 GB/T267-1988
Model Number SH106BR
Minimum Order Quantity 1
Packaging Details wooden case
Delivery Time 7-15 work days
Payment Terms T/T
Supply Ability 10000 sets/year

Contact me for free samples and coupons.

WhatsApp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
Temp Measurement Range Room Temp ~ 400 ℃ Repeatability Flash Point ≤ 150 ℃, Error ± 2 ℃; Flash Point ≥ 150 ℃, Error ± 3 ℃
Resolution 0.1 ℃ Accuracy 0.5%
Ignition Method Electronic Ignition, Gas Flame 3mm~4mm Environmental Temperature (10~40) ℃
Display Mode Color LCD Screen Working Power Supply AC220V ± 10% 50HZ
Leave a Message
Product Description

SH106BR Fully automatic open flash point and ignition point tester

The SH106BR fully automatic open flash point and ignition point tester is designed and manufactured according to the requirements specified in the Chinese standards GB/T 3536 "Determination of Flash Point and Ignition Point of Petroleum Products (Cleveland Open Cup Method)" ASTMD92 and GB/T267-1988, ASTMD92 "Determination of Flash Point and Ignition Point of Petroleum Products (Open Cup Method)", and MT/T1203-2023 "Safety Testing and Inspection Specification for Air Compressors in Coal Mines" for lubricating oil open flash point of air compressors.

Open flash point testers are commonly used for lubricating oils and heavy petroleum products, as the vapor formed by the heated petroleum products continuously diffuses into the surrounding air, resulting in a higher measured flash point. For most lubricating oils and heavy oils, especially when used in non sealed parts or under low temperature conditions, even a small amount of lightweight additives will evaporate during use, without posing a risk of fire or explosion. Therefore, these products are measured using an open flash point tester.

Product model SH106BR
Product Name Fully Automatic Open Flash Point and Ignition Point Tester
Manufacturer Shandong Shengtai Instrument Co., Ltd
Testing items able to meet the requirements of petroleum, chemical, railway, aviation, power, commercial inspection and scientific research units for petroleum product testing
Compliance with standards GB/T 3536ASTMD92 "Determination of Flash Point and Ignition Point of Petroleum Products (Cleveland Open Cup Method)" and GB/T267-1988, ASTMD92 "Determination of Flash Point and Ignition Point of Petroleum Products (Open Cup Method)
Simple technical features Full Chinese human-machine dialogue interface, unmarked keyboard, with prompt menu and guided input function for parameters such as temperature, sample label, atmospheric pressure, and test date that can be predicted.

Fully Automatic Open Flash Point And Ignition Point Tester ASTMD92 Accuracy 0.5% 0

Main technical indicators, parameters, and characteristics

● This instrument adopts a color LCD large screen display, a fully Chinese human-machine dialogue interface, an unmarked keyboard, and has prompt menu and guided input functions for parameters such as temperature, sample number, atmospheric pressure, and test date that can be preset.

● Simulate and track the function curve of temperature rise and test time, with Chinese misoperation software prompt modification function, equipped with parameter prompt functions such as test date and test time.

● Automatically calibrate the impact of atmospheric pressure on the experiment and calculate the correction value.

● Differential detection, automatic correction of system deviation.

● Scanning, detection, and printing data are automatically completed, and the test arm is automatically raised and lowered.

● Electronic ignition, forced air cooling

● Can automatically ignite without the need for a gas source, improving the safety of the test

● Working power supply: AC220V ± 10%, 50Hz

● Temperature measurement: Range: Room temperature to 400 ℃;

● Repeatability: Flash point ≤ 150 ℃ error ± 2 ℃ Flash point ≥ 150 ℃ error ± 3 ℃

● Resolution: 0.1 ℃; Accuracy: 0.5%;

● Heating rate: in accordance with GB/T3536 standard;

● Ignition method: electronic ignition, gas flame 3mm~4mm;

● Environmental temperature: (10~40) ℃;

● Relative humidity: ≤ 80%;

Display mode Color LCD screen
Working power supply AC220V ± 10% 50HZ
Temp measurement range Room temp ~ 400 ℃
Repeatability

Flash point ≤ 150 ℃, error ± 2 ℃;

Flash point ≥ 150 ℃, error ± 3 ℃

Resolution 0.1 ℃
Accuracy 0.5%
Heating rate GB/T3536
Ignition method electronic ignition, gas flame 3mm~4mm
Environmental temperature (10~40) ℃
Relative humidity ≤ 80%

Note: The appearance pictures, dimensions, volume, and weight of the instrument are for reference only. If there are any updates to the instrument, there may be slight changes without prior notice

Fully Automatic Open Flash Point And Ignition Point Tester ASTMD92 Accuracy 0.5% 1

Packing List

Number Name Quantity Unit Note
1 Automatic open flash point tester 1 Unit  
2 Oil cup 1 Piece  
3 AC power cord 1 Root  
4 Printing paper 1 Roll  
5 Operation instructions 1 Piece  
6 Packing list 1 Copy  
7 Certificate 1 Copy