Product Details:
|
Name: | Petroleum Kinematic Viscosity Tester For Diesel And Fuel Oil | Key Words: | Kinematic Viscosity Tester |
---|---|---|---|
Standard: | ASTM D445 | Warranty:: | 1year, |
Place Of Origin:: | Shandong, China | Model Number:: | SH112 |
Temperature Control Range:: | Room Temperature To 100℃ | ||
High Light: | agronomy lab instruments,leaf area measuring instrument |
SH112 Petroleum kinematic viscosity tester conforms to the national standard GB/T265 "Petroleum product kinematic viscosity measurement method and dynamic viscosity calculation method" standard requirements.
It can be used as high viscosity constant temperature water bath for other experiments.
The temperature measurement adopts precision platinum resistor PT100, which can be set arbitrarily from 10 ℃ to 100℃.
Automatic calculation of viscosity value, the product also conforms to ASTM D445.
ASTM D445 Petroleum kinematic viscosity tester for Diesel and fuel oil
Technical data
Performance Standards | GB265-88,,ASTM D445 |
Capillary Viscometer | Conform to SH/T0173-92 Technical Conditions of Glass Capillary Viscometer, Conform to JJG155 Verification Regulation of Routine Capillary Viscometer |
Determination and cleaning | Visual observation, manual cleaning and automatic timing |
Method of Display | 7 inch color LCD |
Temperature Control Range | Room temperature-100℃ |
decision procedure | Visual observation, automatic calculation |
Testing Range | Kinematic Viscosity:0.5~20000mm2/s |
Temperature Control Accuracy | ±0.1℃ |
Timing Accuracy | ±0.1S |
Timing Range | 0.1S-999.9S |
Printer | Thermal printer, high-speed and lower consumption, with 55 millimeter-wide printing paper |
Temperature Testing Components | Precise imported platinum electric resistance |
Heating power | 1800W |
Sample Installing Quantities | 2pieces |
Working Environment | Temperature: 0℃~40℃ Relative Humidity: <80% |
Power Supply | AC220V±10% 50Hz |
Dimension(largest) | 360*370*520(L*W*H) |
Weight | 20Kg |
Performance Standards | GB265-88,,ASTM D445 |
Capillary Viscometer | Conform to SH/T0173-92 Technical Conditions of Glass Capillary Viscometer, Conform to JJG155 Verification Regulation of Routine Capillary Viscometer |
Method of Display | 7 inch color LCD |
Temperature Control Range | Room temperature-100℃ |
Testing Range | Kinematic Viscosity:0.5~20000mm2/s |
Temperature Control Accuracy | ±0.1℃ |
Timing Accuracy | ±0.1S |
Timing Range | 0.1S-999.9S |
Homoeothermic Bathtub | 300×300mm double layer |
Printer | Thermal printer, high-speed and lower consumption, with 55 millimeter-wide printing paper |
Temperature Testing Components | Precise imported platinum electric resistance |
Heating power | 800W |
Sample Installing Quantities | 4 pieces |
Working Environment | Temperature: 0℃~40℃ Relative Humidity: <80% |
Power Supply | AC220V±10% 50Hz |
Dimension(largest) | 360*370*520(L*W*H) |
Weight | 15Kg |
The main features are as follows:
1.The constant temperature bath is a round glass tank with even temperature distribution in the bath and good temperature control effect
2,the instrument adopts precision digital temperature controller to control the temperature in the bathtub, the executive components are solid-state relay SSR, with temperature control accuracy and accuracy, no contact, no noise, no spark, fast action, long life and other characteristics.
3, Capillary card adopts three point vertical type, flexible and convenient operation, reliable clamping.
4, the viscosity tube can be selected according to the needs of the viscosity tube or wusoll viscosity tube.
5. With U disk input function, data can be output to PC for long-term storage.
Technical parameters:
Temperature control point: room temperature -100℃ arbitrary setting;
Temperature control accuracy: ±0.1℃;
Display mode: digital display;
Stopwatch timing: 0.05 seconds --99 minutes 99.99 seconds;
Heating power: 1800W;
Power supply: AC 220V±10%, 50Hz ±5%;
Ambient temperature: 5℃-40℃;
Ambient humidity: < 85%;
Weight: 15Kg.
Contact Person: Weisufen
Tel: +8613370527859