ST-1096A Mycotoxin Tester 800nm Lab Test Instruments

Certification
China Shandong Shengtai instrument co.,ltd certification
I'm Online Chat Now

ST-1096A Mycotoxin Tester 800nm Lab Test Instruments

ST-1096A Mycotoxin Tester 800nm Lab Test Instruments
ST-1096A Mycotoxin Tester 800nm Lab Test Instruments ST-1096A Mycotoxin Tester 800nm Lab Test Instruments

Large Image :  ST-1096A Mycotoxin Tester 800nm Lab Test Instruments

Product Details:
Place of Origin: CHINA
Brand Name: Shengtai instrument
Model Number: ST-1096A
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: 36800
Packaging Details: Wooden box
Delivery Time: About 5 working days
Payment Terms: T/T
Supply Ability: 1000 set per mouth

ST-1096A Mycotoxin Tester 800nm Lab Test Instruments

Description
Light Source: Imported Halogen Lamp, Energy-saving Design Measurement Channel: Vertical 8 Optical Path, Automatically Find The Center
Wavelength Range: 400 - 800nm Reading Range: 0.000 - 4.000Abs(405nm)
Linear Range: 0.000 - 3.000Abs(405nm) Repetition: CV≤0.3%
High Light:

800nm Mycotoxin Tester

,

800nm Mycotoxin Test Instruments

ST-1096A Mycotoxin Tester

 

ST-1096A microplate reader is a necessary analytical instrument for enzyme-linked immunoassay. Adopting the principle of solid-phase enzyme-linked immunosorbent ELISA, that is, enzyme-linked immunoassay, it consists of two parts: the instrument and the B1 kit. It can limit and quantitatively determine the sample. It can generally measure MTT, the relative number and relative viability of cells Determine the absorbance of the sample according to the requirements.
Features

 

Industrial color LCD display, touch screen operation
Eight-channel optical fiber measurement system, imported detector
Precise center positioning function, accurate and reliable
Three linear vibration plate functions, adjustable speed time
Ultra-wide voltage input design, global voltage application
Unique open cut-off judgment formula, set your own
End point method, two-point method, dynamics, single / dual wavelength test mode

 

The main technical parameters
Light Source: Imported halogen lamp, energy-saving design
Measurement channel: vertical 8 optical path channels, automatically find the center
Wavelength range: 400-800nm
Filters: Standard 405, 450, 492, 630nm four standard filters, other wavelengths are optional, up to 10 filters can be loaded
Reading range: 0.000-4.000Abs (405nm)
Linear range: 0.000-3.000Abs (405nm)
Repeatability: CV≤0.3%

Stability: ≤ ± 0.003Abs
Indication error: ≤ ± 0.01Abs
Wavelength error: ≤ ± 2nm
Recognition rate: 0.001Abs (display, print), internal calculation 0.0001Abs
Vibration plate function: vibration plate strength (from weak to strong) 3 levels optional, vibration plate time 0-255 seconds adjustable, error ± 2 seconds
Display input: 8-inch color LCD display, touch screen input
Power input: wide voltage design AC100V-240V 50-60Hz
Product quality: about 11Kg
Dimensions: 433mm (L) * 320mm (W) * 308mm (H)

Reading range 0.000-4.000Abs (405nm)
Linear range 0.000-3.000Abs (405nm)
Repeatability CV≤0.3%
Stability ≤ ± 0.003Abs
Indication error ≤ ± 0.01Abs
Wavelength error ≤ ± 2nm
Recognition rate 0.001Abs (display, print), internal calculation 0.0001Abs
Power input wide voltage design AC100V-240V 50-60Hz

 

Single-machine operation interface
1. Use the direction buttons to select the desired wavelength for measurement;
2. Press the [Layout] button to perform the layout of the blank control and standard in the quantitative analysis, and enter the concentration of the related standard
value. This [Layout] function supports layout before measurement or layout after measurement. For specific settings, see the following quantitative
Layout chapter.
3. Press the [ON / OFF] warehouse button, carefully place the enzyme label plate to be tested, and pay attention to prevent liquid splashing.
4. Press the [Reading Board] button for measurement. During the measurement, do not press the touch screen for other operations;
5. The measured data will be automatically displayed on the LCD screen;
6. Press the [History Curve] button to select the previously stored curve to fit the measured data this time without setting standards

The concentration value of the product can be calculated directly; [Note: When the standard product is placed on the layout interface, calling the historical curve will be invalid]
7. Press [Measured Value] to display the absorbance value after deducting the blank control value, and at the same time update and display the blank pair according to the layout According to (BLK) value;
8. Press the [Concentration] button to calculate and display the concentration value of the sample to be tested according to the layout;
9. You can press the [Save] button to store this measurement data. For specific operations, please refer to the storage section;
10. You can press the [Print] button to print the measurement data;
11. Press the [Back] button to return to the main interface.
12. Equipped with software that can be controlled by computer.