Product Details:
|
Standard: | ASTM D1177 | Automatic: | Semi-automatic |
---|---|---|---|
Working Cold Bath: | Double-layer Vacuum Glass Bath. | Cold Tank Temperature Control: | Cold Tank Temperature Control |
Temperature Control Accuracy: | ±0.1℃ | Bath Liquid Stirring: | The Stirring Motor Can Stir Automatically |
Refrigeration System: | New Type Refrigeration Compressor | Temp Rang: | +30degree To -70 Degree |
High Light: | ASTM D1177 freezing point tester,ASTM D2386 freezing point tester |
SH128A semi-automatic antifreeze freezing point tester is designed and manufactured according to the national petrochemical industry standard SH/ t0090-91 "engine coolant freezing point determination method"and ASTMD1177. Suitable for determination of freezing point of engine coolant and its concentrate.
Instrument features: digital temperature controller is used to control alcohol bath, motor and mechanical automatic mixing sample, double motor mixing.
Technical parameters
Working cold tank | double vacuum glass bath. |
cold tank temperature control | +30℃ ~ -70℃ |
Temperature control accuracy | ±0.5℃ |
Bath liquid stirring |
the stirring motor stirs automatically, with a power of 6W and 1200r/min.
|
Refrigeration system | compressor refrigeration |
Sample stirring | synchronous deceleration motor, 60 times/min |
Ambient temperature | ≤30℃ |
Relative humidity | ≤85% |
Power consumption of the whole machine | about 1500W |
SH128A semi-automatic antifreeze freezing point tester is designed and manufactured according to the national petrochemical industry standard ASTM 1177 OR ASTM D2386 "engine coolant freezing point determination method". Suitable for determination of freezing point of engine coolant and its concentrate.
Instrument features: digital temperature controller is used to control alcohol bath, motor and mechanical automatic mixing sample, double motor mixing.
Technical parameters
Working cold tank | double vacuum glass bath. |
cold tank temperature control | +30℃ ~ -70℃ |
Temperature control accuracy | ±0.5℃ |
Bath liquid stirring |
the stirring motor stirs automatically, with a power of 6W and 1200r/min.
|
Refrigeration system | compressor refrigeration |
Sample stirring | synchronous deceleration motor, 60 times/min |
Ambient temperature | ≤30℃ |
Relative humidity | ≤85% |
Power consumption of the whole machine | about 1500W |
Technical parameters
Working cold tank | double vacuum glass bath. |
cold tank temperature control | +30℃ ~ -70℃ |
Temperature control accuracy | ±0.5℃ |
Bath liquid stirring |
the stirring motor stirs automatically, with a power of 6W and 1200r/min.
|
Refrigeration system | compressor refrigeration |
Sample stirring | synchronous deceleration motor, 60 times/min |
Ambient temperature | ≤30℃ |
Relative humidity | ≤85% |
Power consumption of the whole machine | about 1500W |
Contact Person: Tang
Tel: +8615665870097