Home ProductsLubricating Oil And Grease Antifreeze Testing Instruments

Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods

Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods

Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods
Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods

Large Image :  Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods

Product Details:
Place of Origin: china
Brand Name: shandongshengtai
Model Number: SH103
Payment & Shipping Terms:
Minimum Order Quantity: 11
Packaging Details: wooden case
Delivery Time: 5-8work days
Payment Terms: T/T
Supply Ability: 100 set per month

Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods

Description
Name: Automatic Lubricating Oil Moisture Meter Power Source: AC 220V ± 10% 50Hz ± 10%
Titration Speed: 2.5mg / Min (maximum)
High Light:

lube oil analysis equipment

,

oil moisture meter

 

 

 

 

   SH103 Trace moisture tester is designed and made as per national standard of China GB/T 7600 Standard Test Method for Water Content of Transformer Oil in Service (Coulometric Method), industrial standard of China SH/T0246 Standard Test Method for Water Content of Light Oils (Coulometry). ASTM D1533 Standard Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration and ASTM D6304 Standard Test Method for Determination of Water in Petroleum Products,Lubricating Oils and Additives by Karl Fischer Titration. It is used to determine moisture content in the liquid petroleum

Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods 0

products.

 I. Main technical features ASTM D6304 ASTM D1533 Karl Fischer Methods

1. LCD screen. It has screen protection function. The LCD screen will shut off if there is no operation for a long period.

2. High precision measuring electrode make it rapidly and accurately to find the end point.

3. It adopts electrolyte blank current compensation and equilibrium point drift compensation, two methods to correct measurement result.

4. It has automatic detecting function for open-circuit fault and short-circuit fault of measuring electrode.

5. It can save at most 255 data with time mark.

Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods 1

II. technical specifications

1. Amount and precision of electrolyzed water: 1) 10ug~1000ug,±2ug 2) >1000ug,0.2%

2. Measurement range: 0~100 mg (The percentage is from 0.00001% to 100%)

3. Resolution: 0.1ug

4. Maximum electrolysis speed: 40ug/s

5. Power supply: AC 220V±20%, 50 Hz

6. Maximum power consumption: 30 W

7. Ambient temperature: 10℃~35 ℃

8. Relative humidity: ≤85%

9. Dimension: 320mm×240mm×150mm

10. Net weight: 8kg

Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods 2

  SH103 Trace moisture tester is designed and made as per national standard of China GB/T 7600 Standard Test Method for Water Content of Transformer Oil in Service (Coulometric Method), industrial standard of China SH/T0246 Standard Test Method for Water Content of Light Oils (Coulometry). ASTM D1533 Standard Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration and ASTM D6304 Standard Test Method for Determination of Water in Petroleum Products,Lubricating Oils and Additives by Karl Fischer Titration. It is used to determine moisture content in the liquid petroleum

Technical parameters:

Method Karl Fischer Coulometric Titrator Principle
Measuring Range 0.00001% to 100%
Resolution 0.1ug
the Largest Electrolytic Speed 40 ug/s
Power Supply Voltage AC220V ±20%( customization)
Largest power 30w
Work Temperature 10~35℃
Work Humidity ≤85%
Dimensions 320*240*150mm
Weight 8kg
 

 

   ASTM D1533, ASTM D6304 Automatic Oil Moisture Analyzer Coulometric Karl Fischer Titrator

 

SH103 Trace moisture tester is designed and made as per national standard of China GB/T 7600 Standard Test Method for Water Content of Transformer Oil in Service (Coulometric Method), industrial standard of China SH/T0246 Standard Test Method for Water Content of Light Oils (Coulometry). ASTM D1533 Standard Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration and ASTM D6304 Standard Test Method for Determination of Water in Petroleum Products,Lubricating Oils and Additives by Karl Fischer Titration. It is used to determine moisture content in the liquid petroleum

Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods 3
 

 

 

 

Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods 4

Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods 5

Fast Speed Lubricating Oil Moisture Meter , Trace Moisture Analyzer ASTM D6304 ASTM D1533 Karl Fischer Methods 6 

Contact Details
Shandong Shengtai instrument co.,ltd

Contact Person: Weisufen

Tel: +8613370527859

Send your inquiry directly to us (0 / 3000)