Automatic Cleaning Transformer Oil Dielectric Loss and Volume Resistivity Test SH124

Place of Origin CHINA
Brand Name Shengtai instrument
Certification ISO9001
Model Number SH124
Minimum Order Quantity 1
Packaging Details wooden case
Delivery Time 7-15work-days
Payment Terms T/T
Supply Ability 100000sets/year

Contact me for free samples and coupons.

WhatsApp:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
MODEL SH124 Executive Standard DL/T421, GB/T5654
Test Range 2.0 X 105 ~ 1.0 X 1013 Ω M. Constant Temperature Time 0 ~ 59 Minutes
Charging Time 0 ~ 99 Seconds Empty Cup Capacitance 30.0pF
Electrode Spacing 2.0mm
High Light

5500 r/min Lab Test Instruments

,

150w Lab Test Instruments

,

Rice hulling machine

Leave a Message
Product Description

SH124 automatic volume resistivity tester is designed and manufactured according to the requirements of the People's Republic of China power industry standard DL/T421-2009 and the national standard GB/T5654. It is used for measuring the volume resistivity of liquid media such as insulating oil and fuel oil.

SH124 automatic volume resistivity measuring instrument adopts MCS-51 series MCU as the system control core, color LCD display, Chinese man-machine dialogue, guide operation, the measurement process is fully automated (automatic cup change, automatic shift), and rolling storage of 200 test data;

And combined with modern new technology developed from.

The whole equipment of advanced design, reasonable structure, simple operation, safe and reliable, is the contemporary technology level of same sort products at home and abroad the highest performance index, the most perfect resistivity tester, particularly useful in the application of oil monitoring, power sector test results accord with national standard DL421-91 the insulating oil volume resistivity measurement.

Automatic Liquid Tangent Delta Dielectric Loss and Volume Resistivity Tester for Insulation Oil

Fully Automatic Tangent Delta Tester Oil Dielectric Loss and Volume Resistivity Tester for Insulation Oil

Automatic Cleaning Transformer Oil Dielectric Loss and Volume Resistivity Test

Automatic Insulating Oil Dielectric Loss and Volume Resistivity Tester

Technical parameters

Executive standard: DL/T421, GB/T5654

Test range: 2.0 x 105 ~ 1.0 x 1013 Ω m.

Test accuracy: repeatability:

Volume resistivity > 1.0 x 1010 Ω m., the relative error of 25%

Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 15%

Reproducibility:

Volume resistivity > 1.0 x 1010 Ω m., the relative error of 35%

Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 25%

Test voltage: 500 VDC maximum error 0.5 %

Constant temperature time: 0 ~ 59 minutes

Charging time: 0 ~ 99 seconds

Discharge time: 0 ~ 9 minutes

Temperature control range: 15 ~ 100℃, temperature control accuracy ±0.5℃

Electrode cup parameters:

Electrode type: three terminal electrode, internal and external electrode double temperature control

Electrode material: special steel

Insulation material: PTFE

Electrode spacing: 2.0mm

Empty cup capacitance: 30.0pF

Empty glass insulation resistance: > 3.0 x 1012 Ω

Power source: AC 220V± 10%, 50Hz± 5%

Power: 500 w or less

Working environment: temperature 10 ~ 35℃, humidity ≤ 85%

 

Executive standard DL/T421, GB/T5654
Test range 2.0 x 105 ~ 1.0 x 1013 Ω m.
Test accuracy: repeatability

 

Volume resistivity > 1.0 x 1010 Ω m., the relative error of 25%

Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 15%

Reproducibility  

 

Volume resistivity > 1.0 x 1010 Ω m., the relative error of 35%

Volume resistivity 1.0 x 1010 or less Ω m., the relative error is 25%

 

Test voltage: 500 VDC maximum error 0.5 %

 

Constant temperature time

0 ~ 59 minutes

 

Charging time 0 ~ 99 seconds
Discharge time 0 ~ 9 minutes
Temperature control range 15 ~ 100℃, temperature control accuracy ±0.5℃
Electrode type three terminal electrode, internal and external electrode double temperature control
Electrode material

special steel

 

Insulation material PTFE
Electrode spacing 2.0mm
Empty cup capacitance 30.0pF
Empty glass insulation resistance > 3.0 x 1012 Ω
Power source AC 220V± 10%, 50Hz± 5%
Power 500 w or less
Working environment temperature 10 ~ 35℃, humidity ≤ 85%
     

Packing list

S/N Name Quantity Unit Remarks
1 Host 1 set  
2 Electrode cup 1 set  
3 power cord 1 piece  
4 Instructions 1 copy  
5 Packing list 1 copy  
6 Certificate warranty card 1 copy  

Automatic Cleaning Transformer Oil Dielectric Loss and Volume Resistivity Test SH124 0Automatic Cleaning Transformer Oil Dielectric Loss and Volume Resistivity Test SH124 1Automatic Cleaning Transformer Oil Dielectric Loss and Volume Resistivity Test SH124 2

Company Introduction

Shandong Shengtai Instruments Co., Ltd. is specialized in the research and production of experimental testing instruments and industrial testing instruments. It is a professional instrument company integrating instrument research and development, manufacturing, sales and service. Its products are widely used in food, flour, grain and oil, Feed, electricity, petrochemical, industrial oil, aerospace, coal quality and other industries.

For more than 10 years, Shengtai has always been adhering to the "first-class service, customer first" as the purpose, "reasonable price, honesty and trustworthiness" as the business policy. Adhere to technical innovation, with rich knowledge of the technical team and experienced, thoughtful after-sales service team.

Shengtai instrument as one of the most large-scale and competitive enterprises in the industry, with the strength of technology research and development, professional technical knowledge and innovative design concept, in the model improvement, Significant technical breakthrough has been achieved in the development of function expansion and intelligent control system.

OUR service

After-sales service commitment, our company to sell the product after-sales service commitment: warranty period of one year, long-term technical support outside the warranty period. During the warranty period, the seller shall bear the cost of the replacement of the equipment, the freight and maintenance of the instrument; outside the warranty period, the seller shall waive the maintenance fee and charge only the cost of the basic materials and freight charges when the instrument is malfunctioning and the seller shall not charge the maintenance fee during the warranty period.

Packaging & Delivery

1. Out packing: Standard export wooden case.
2. Inner packing: With careful stretch film wrap product, hard wood board+ strong bandage to fix corners.
3. Checking teams: Specialized staff to inspect and classified your goods.

4.Port Any port of China

Lead Time :

Quantity(Sets) 1 - 1 2 - 5 6 - 10 >10
Est. Time(days) 6 20 30 To be negotiated

Contact us

Shandong Shengtai Instrument Co.,ltd

ADD:6-8 time base NO.15 lanxiang road tianqiao Area Jinan city

TEL:+86 0531-85919987 85929987

FAX:+86 0531-85957987

Whatsapp/facebook:+86 13370527859

QQ:3206156217

Email:3206156217@qq.com

Web:www.labtool.net/en