Method for flash point detection of coatings

November 1, 2021
Latest company news about Method for flash point detection of coatings

Method for flash point detection of coatings

latest company news about Method for flash point detection of coatings  0

According to the national standard GB 3186-82 "Sampling of coating products", take out representative coating samples from the coating products to be tested.
Before the test, the sample should be placed in an airtight container, and the free volume in the container should not exceed 10% of the total container volume. Samples should not be stored in plastic bottles (e.g. polyethylene, polypropylene, etc.).
Coating flash point detection using GB/T5208 flash point determination of fast balance cup method to determine, Shandong Sheng Tai Instrument Co., Ltd. research and development of SH105D balance method low temperature closed flash point instrument is in accordance with the People's Republic of China standard GB/T5208 "flash point determination of fast balance closed cup method" requirements of the design and manufacture, The results can be stored in a microcomputer or stored on a USB disk. The instrument also meets the requirements of ISO 1523 and ISO 3679 standards.
The instrument is especially suitable for the test of the flash point of the closed cup of all kinds of paints, paints, adhesives, solvents, petroleum and related products within the range of -30℃ ~ +100℃.


Main technical indicators and parameters
1. Upgrade to 7-inch touch color screen display
2, flash point detection range: (-30 ~ +100)℃;
3, measurement precision: the absolute difference between the two experimental results is less than 2℃ (the same operator);
The absolute difference between the two experimental results is less than 3℃ (different operators).
4, temperature control accuracy: ±0.1℃;
5, ignition device: electronic ignition;
6, refrigeration mode: semiconductor internal refrigeration and external compressor refrigeration cycle
7, after the upgrade can store 199 groups of historical data, easy to query; At the same time can U disk output function
8, laser printer interface, HP1108 laser printer can be linked (optional)
9, with date password setting function.
10, standard micro printer automatic measurement automatic thermal printing
11, with TCP network transmission function
12. Limis system can be uploaded and connected
13, meet the standard: meet the Chinese standard GB/T5208-2008, GB5207, GB7634, GB/T21790
14, power supply voltage: AC220V± 10%, 50Hz;
15, power consumption: no more than 300W
16, ambient temperature: 5℃ ~ 30℃;
17, relative humidity: (30 ~ 80)%.